DESCRIPTION OF A HIGH-SENSITIVITY CW SCALAR DNP-NMR MAGNETOMETER

被引:27
作者
KERNEVEZ, N
GLENAT, H
机构
[1] CEA-DTA-LETI, 38041, Grenoble
关键词
D O I
10.1109/20.278852
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The earth field NMR magnetometer is a field/frequency transducer based on the principle of nuclear magnetic resonance amplified by using dynamic nuclear polarization. The double DNP is used to design the sensor as a continuous wave oscillator. The sensor is highly sensitive (10(-11), Isotropic and without thermal drift. It's a useful detector in miscallaneous sectors such as anti-submarine warfare or oil drilling.
引用
收藏
页码:5402 / 5404
页数:3
相关论文
共 5 条
[1]  
ABRAGAM A, 1961, PRINCIPLES NUCLEAR M
[2]   THEORETICAL INTERPRETATION OF THE LINE-SHAPE OBTAINED BY DYNAMIC POLARIZATION IN SOLUTIONS OF FREE-RADICALS [J].
AYANT, Y ;
BESSON, R ;
CASALEGNO, R .
JOURNAL DE PHYSIQUE, 1980, 41 (10) :1183-1192
[3]  
AYANT Y, 1991, 25TH C AMP RES MAG
[4]  
COLLIN CR, 1973, GEOPHYS PROSPECTING, V21
[5]  
POCACHARD J, 1991, AUG IAGA VIENN, P11