OXYGEN MEMBRANE-ELECTRODE USED AS A TOXICITY BIOSENSOR

被引:5
作者
GOLDBLUM, DK
HOLODNICK, SE
MANCY, KH
BRIGGS, DE
机构
[1] School of Public Health, University of Michigan, Ann Arbor, Michigan
[2] College of Engineering, University of Michigan, Ann Arbor, Michigan
[3] USAF, Occupational and Environmental Health Laboratory, Brooks AFB, Texas
来源
ENVIRONMENTAL PROGRESS | 1991年 / 10卷 / 01期
关键词
D O I
10.1002/ep.670100112
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Three biosensor configurations that included a dissolved oxygen electrode and yeast cells (Saccharomyces cerevisiae) were evaluated as a means to assess the environmental effects of toxic chemicals. The configurations were: closed suspension-assay medium closed to air and cells suspended in the medium; open suspension-assay medium open to air and cells suspended in medium; and biofilm electrode (BFE)-assay medium open to air but cells immobilized on the surface of the electrode. The BFE was the most advantageous configuration based on assay times and detection limits.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 43 条
[11]  
Smart R.B., Herrera R.D., Mancy K.H., In Situ Voltammetric Membrane Ozone Electrode, Analytical Chemistry, 51, (1979)
[12]  
Herrera R.D., Mancy K.H., Voltammetric Membrane Chlorine Dioxide Electrode, Analytical Letters, 13, 7 A, (1980)
[13]  
Clark L.C., Duggan C.A., Implanted Electroenzymatic Glucose Sensors, Diabetes Care, 5, 3, (1982)
[14]  
Cleland N., Enfors S.O., Monitoring Glucose Consumption in Escherichia Coli Cultivation with an Enzyme Electrode, Analytica Chimica Acta, 163, (1984)
[15]  
Gough D.A., Lucisano J.Y., Tse P.H.S., Two‐Dimensional Enzyme Electrode Sensor for Glucose, Analytical Chemistry, 57, (1985)
[16]  
Olsson B., Lundbock H., Johanson G., Theory and Application of Diffusion‐Limited Amperometric Enzyme Electrode Detection in Flow Injection Analysis of Glucose, Analytical Chemistry, 58, (1986)
[17]  
Sonawat H.M., Ratna S.P., Govil G., Covalent Immobilization of FAD and Glucose Oxidase on Carbon Electrodes, Biotechnology and Bioengineering, 26, (1984)
[18]  
Wiech H.J., Heider G.H., Yacyncyh A.M., Chemically Modified Reticulated Vitreous Carbon Electrode with Immobilized Enzyme as a Detector in Flow‐Injection Determination of Glucose, Analytica Chimica Acta, 158, (1984)
[19]  
Szuminsky N.J., Chen A.K., Liu C.C., A Miniature Palladium‐Palladium Oxide Enzyme Electrode for Urea Determination, Biotechnology and Bioengineering, 26, (1984)
[20]  
Cenas N., Rozgaite J., Kulys J., Lactate, Pyruvate, Ethanol, and Glucose‐6‐Phosphate Determination by Enzyme Electrode, Biotechnology and Bioengineering, 26, (1984)