SUPPRESSION OF MOTION ARTIFACTS IN FLUORESCENCE SPECTROSCOPY OF PERFUSED HEARTS

被引:50
作者
BRANDES, R
FIGUEREDO, VM
CAMACHO, SA
MASSIE, BM
WEINER, MW
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT MED CARDIOL,CARDIOVASC RES INST,SAN FRANCISCO,CA 94143
[2] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,SAN FRANCISCO,CA 94143
来源
AMERICAN JOURNAL OF PHYSIOLOGY | 1992年 / 263卷 / 03期
关键词
REDUCED NICOTINAMIDE ADENINE DINUCLEOTIDE; CALCIUM; INDO-1; SCATTERING; AUTOFLUORESCENCE;
D O I
10.1152/ajpheart.1992.263.3.H972
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Fluorescence spectroscopy of beating hearts has been used previously to measure intracellular regulators of function. Unfortunately, heart motion could introduce a spurious motion artifact (MA), influencing the measured fluorescence intensity ("signal"). To suppress MA, a ratio (or difference) has been calculated previously between the signal and an intensity reference detected at a different wavelength ("reference"). However, no studies have attempted to evaluate or optimize the efficiency of MA suppression. MA suppression was evaluated using reflected excitation light or fluorescence as reference. In addition, the MA contribution to the intensity ratio from a fluorescent dye, indo-1, was quantified. A reflected light reference resulted in poor suppression of MA. The use of a fluorescence reference resulted in suppression that was inversely related to the detection wavelength difference (DELTA) between the reference and signal. Therefore optimal MA suppression was obtained using a fluorescence reference at a wavelength close to the signal. For DELTA = 60 nm, MA was suppressed from approximately 10 to <2%. Finally, suppressed MA (DELTA = 60 nm) accounted for <10% of the indo-1 ratio fluctuations.
引用
收藏
页码:H972 / H980
页数:9
相关论文
共 15 条
[1]  
BRANDES R, 1991, CIRCULATION S2, V84, P402
[2]  
CHANCE B, 1965, BIOCHEM Z, V341, P357
[3]   EFFECTS OF TISSUE ABSORBENCY ON NAD(P)H AND INDO-1 FLUORESCENCE FROM PERFUSED RABBIT HEARTS [J].
FRALIX, TA ;
HEINEMAN, FW ;
BALABAN, RS .
FEBS LETTERS, 1990, 262 (02) :287-292
[4]  
GRYNKIEWICZ G, 1985, J BIOL CHEM, V260, P3440
[5]  
HEINEMAN FW, 1991, CIRCULATION S2, V84, P276
[6]  
JOEBSIS FF, 1968, RESPIR PHYSL, V4, P292
[7]  
KORETSKY AP, 1987, AM J PHYSIOL, V253, pH862
[8]   CEREBRAL CORTICAL MICRO-FLUOROMETRY AT ISOSBESTIC WAVELENGTHS FOR CORRECTION OF VASCULAR ARTIFACT [J].
KRAMER, RS ;
PEARLSTEIN, RD .
SCIENCE, 1979, 205 (4407) :693-696
[9]  
LAKOWICZ JR, 1983, PRINCIPLES FLUORESCE, P95
[10]  
LEE HC, 1988, CIRCULATION, V78, P4947