TRANSMISSION OF CORNEAL COLLAGEN DURING ARF EXCIMER LASER ABLATION

被引:23
作者
EDIGER, MN [1 ]
PETTIT, GH [1 ]
WEIBLINGER, RP [1 ]
CHEN, CH [1 ]
机构
[1] JOHNS HOPKINS UNIV,SCH MED,WILMER OPHTHALMOL INST,BALTIMORE,MD 21205
关键词
PHOTOABLATION; PHOTOREFRACTIVE KERATOPLASTY; ULTRAVIOLET;
D O I
10.1002/lsm.1900130208
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
The time-resolved transmission of collagen films and 10-mum sections of bovine cornea during ArF laser ablation has been investigated. The film studies were performed on thin layers of extracted bovine corneal collagen, the principal chromophore in 193 nm photoablation. Transmission measurements were made on both dry and water-saturated films to assess the sensitivity of the ablation process to hydration. Distinct transient optical changes were observed in both fully desiccated and rehydrated films. Dehydrated films exhibit rapid reduction in film absorption over the time-course of the ablating laser pulse, presumably due to chromophore bleaching or annihilation. In contrast, rehydrated films demonstrate a short-lived enhancement of the attenuation. In either case, a single ablative laser pulse increased the long-term transmission of the film, although this increase was a factor of five greater for dehydrated films than for rehydrated samples. Results obtained from corneal tissue sections were essentially identical to those derived from hydrated collagen films.
引用
收藏
页码:204 / 210
页数:7
相关论文
共 17 条
[1]   TIME-RESOLVED REFLECTIVITY OF ARF LASER-IRRADIATED POLYIMIDE [J].
EDIGER, MN ;
PETTIT, GH .
JOURNAL OF APPLIED PHYSICS, 1992, 71 (07) :3510-3514
[2]   EFFECT OF EXCIMER LASER RADIANT EXPOSURE ON UNIFORMITY OF ABLATED CORNEAL SURFACE [J].
FANTES, FE ;
WARING, GO .
LASERS IN SURGERY AND MEDICINE, 1989, 9 (06) :533-542
[3]   CONTROLLED LENS FORMATION WITH UNAPERTURED EXCIMER LASERS - USE WITH ORGANIC POLYMERS AND CORNEAL TISSUES [J].
FUXBRUNER, A ;
HEMO, I ;
LEWIS, A ;
ZAUBERMAN, H ;
BLAU, D ;
POLOTSKY, D .
APPLIED OPTICS, 1990, 29 (36) :5380-5386
[4]  
GORDON M, 1992, SPIE P
[5]   THE PHYSICS OF UV LASER CORNEA ABLATION [J].
KITAI, MS ;
POPKOV, VL ;
SEMCHISHEN, VA ;
KHARIZOV, AA .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1991, 27 (02) :302-307
[6]  
KRUEGER RR, 1985, ARCH OPHTHALMOL-CHIC, V103, P1741
[7]  
MARSHALL J, 1985, OPHTHALMOLOGY, V92, P749
[8]   TIME-RESOLVED REFLECTIVITY AS A PROBE OF THE DYNAMICS OF LASER ABLATION OF ORGANIC POLYMERS [J].
PARASKEVOPOULOS, G ;
SINGLETON, DL ;
IRWIN, RS ;
TAYLOR, RS .
JOURNAL OF APPLIED PHYSICS, 1991, 70 (04) :1938-1946
[9]   EXCIMER LASER CORNEAL ABLATION - ABSENCE OF A SIGNIFICANT INCUBATION EFFECT [J].
PETTIT, GH ;
EDIGER, MN ;
WEIBLINGER, RP .
LASERS IN SURGERY AND MEDICINE, 1991, 11 (05) :411-418
[10]  
PETTIT GH, 1992, IN PRESS APPL OPTICS