HIGH-TECHNOLOGY TO SIMPLIFY THE PLANNING AND DELIVERY OF RADIOTHERAPY

被引:5
作者
HOUNSELL, AR
MARRS, JE
MOORE, CJ
SHARROCK, PJ
SHAW, AJ
WILKINSON, JM
WILLIAMS, PC
机构
[1] North Western Medical Physics Department, Christie Hospital, Manchester
关键词
MULTI-LEAF COLLIMATORS; TREATMENT PLANNING; CONFORMAL THERAPY;
D O I
10.1016/0167-8140(93)90246-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Two techniques for the automatic selection of individual leaf positions of a Philips multi-leaf collimator are described. Target volumes are identified either on simulator images or on cross-sectional images from CT or MR scanners. The setting of each leaf is computed to position the beam edge to cover the target with an appropriate, user defined, margin. An important consideration in the development of the system was its robustness and so the applications initially implemented have been relatively simple, comprising single field, parallel opposed fields and coplanar 4 field box techniques. Attention has been paid to the overall integrity of the planning and treatment delivery process. Before treatment commences, the beam shapes, which have been generated by the computer and transferred to the MLC control computer over a local area network, are checked against a printed template representing each beam. All data used for planning is archived and is accessible for review or, if necessary, for treatment modification.
引用
收藏
页码:192 / 196
页数:5
相关论文
共 14 条
[1]   CONFORMATION THERAPY AT THE ROYAL FREE HOSPITAL - A PROGRESS REPORT ON THE TRACKING COBALT PROJECT [J].
BRACE, JA ;
DAVY, TJ ;
SKEGGS, DBL ;
WILLIAMS, HS .
BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (648) :1068-1074
[2]  
BRAHME A, 1988, STRAHLENTHER ONKOL, V164, P343
[3]   OPTIMIZATION OF STATIONARY AND MOVING BEAM RADIATION-THERAPY TECHNIQUES [J].
BRAHME, A .
RADIOTHERAPY AND ONCOLOGY, 1988, 12 (02) :129-140
[4]   DOSE OPTIMIZATION WITH COMPUTER-CONTROLLED GANTRY ROTATION, COLLIMATOR MOTION AND DOSE-RATE VARIATION [J].
CHIN, LM ;
KIJEWSKI, PK ;
SVENSSON, GK ;
BJARNGARD, BE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (05) :723-729
[5]   A RAPID OPTICAL METHOD FOR PREPARATION OF COMPLEX FIELD SHAPES [J].
EARLE, JD ;
BAGSHAW, MA .
RADIOLOGY, 1967, 88 (06) :1162-&
[6]   THE INVERSE PROBLEM [J].
GOITEIN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (02) :489-491
[7]  
GREEN A, 1960, 9TH T INT C RAD MUNC, P766
[8]   COMPUTER-ASSISTED GENERATION OF MULTI-LEAF COLLIMATOR SETTINGS FOR CONFORMATION THERAPY [J].
HOUNSELL, AR ;
SHARROCK, PJ ;
MOORE, CJ ;
SHAW, AJ ;
WILKINSON, JM ;
WILLIAMS, PC .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (772) :321-326
[9]   METHOD FOR ACCURATE MANUFACTURE OF LEAD SHIELDS [J].
JONES, D .
BRITISH JOURNAL OF RADIOLOGY, 1971, 44 (521) :398-&
[10]   INDIVIDUALIZED LUNG SHIELDS CONSTRUCTED FROM LEAD SHOT EMBEDDED IN PLASTIC [J].
MARUYAMA, Y ;
MOORE, VC ;
BURNS, D ;
HILGER, MTJ .
RADIOLOGY, 1969, 92 (03) :634-&