RESULTS OF THE 1ST INTERNATIONAL GRANULOCYTE SEROLOGY WORKSHOP

被引:18
作者
LUCAS, GF [1 ]
CARRINGTON, PA [1 ]
机构
[1] HOPE HOSP,DEPT HAEMATOL,SALFORD M6 8HD,LANCS,ENGLAND
关键词
D O I
10.1111/j.1423-0410.1990.tb00249.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Eleven laboratories paticipated in the First International Workshop of Granulocyte Serology. Participants were asked to identify any granulocyte‐reactive antibodies present in 12 human sera distributed as unknown samples. Granulocyte immunofluorescence and granulocyte micro‐agglutination were the most commonly used techniques. The incidence of false‐positive and false‐negative reactions was 15 and 4%, respectively. Most laboratories were able to distinguish between granulocyte‐specific and anti‐HLA antibodies using platelet absorption. The identification of the specificity of granulocyte‐specific antibodies caused the most problems; these were correctly identified on only 57% of occasions. © 1990 S. Karger AG, Basel
引用
收藏
页码:251 / 256
页数:6
相关论文
共 15 条
[11]   DIAGNOSTIC AND PATHOGENETIC CONSIDERATIONS IN TRANSFUSION-RELATED ACUTE LUNG INJURY [J].
POPOVSKY, MA ;
MOORE, SB .
TRANSFUSION, 1985, 25 (06) :573-577
[12]   MICRODROPLET ASSAY OF HUMAN SERUM CYTOTOXINS [J].
TERASAKI, PI ;
MCCLELLAND, JD .
NATURE, 1964, 204 (496) :998-&
[13]  
VANLEEUWEN A, 1964, VOX SANG, V9, P431
[14]   DETECTION OF GRANULOCYTE ALLOANTIBODIES WITH AN INDIRECT IMMUNOFLUORESCENCE TEST [J].
VERHEUGT, FWA ;
VONDEMBORNE, AGEK ;
DECARY, F ;
ENGELFRIET, CP .
BRITISH JOURNAL OF HAEMATOLOGY, 1977, 36 (04) :533-544
[15]  
YOMTOVIAN R, 1984, LANCET, V1, P244