CONCENTRATION-DEPENDENCE OF METHYL PALMITATE ISOTOPE RATIOS BY ELECTRON-IMPACT IONIZATION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY

被引:51
作者
PATTERSON, BW
WOLFE, RR
机构
[1] SHRINERS BURNS INST,GALVESTON,TX 77550
[2] UNIV TEXAS,MED BRANCH,DEPT ANESTHESIOL,GALVESTON,TX 77550
关键词
D O I
10.1002/bms.1200220810
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Isotope ratios must be measured precisely when stable isotopic tracers are used for in vivo metabolic kinetic studies since low enrichments are generally achieved above relatively high natural abundance backgrounds. We have observed that the (m + 1)/(m + 0) isotope ratio for the molecular ion of methyl palmitate (measured by electron impact ionization selected ion monitoring ps chromatography/mass spectrometry) is limited by a dependence of the isotope ratio on the quantity of sample analyzed. Since it is not practical to analyze exactly the same quantity of sample in a series of samples, this concentration dependence decreases the apparent precision of the isotope ratio measurement. The apparent natural abundance (m + 1)/(m + 0) isotope ratio increased from approximately 0.185 (0.2 nmol analyzed) to 0.20 (2.0 mmol). The concentration dependence was not altered as the quadrupole tuning resolution was varied and did not appear to arise from system non-linearity. The major source of concentration dependence derived from hydrogen abstraction during ion-molecule collisions within the ionization chamber. The concentration dependence was decreased as the repeller voltage increased and ion residence times in the source were reduced. Furthermore, the integrated (m + 1) peak area increased with the square of the (m + 0) peak area, consistent with a bimolecular ion-molecule collision process. A simple mathematical correction for the concentration dependence afforded a ten-fold improvement in the coefficient of variation of the isotope ratio measurement. Although hydrogen abstraction has been a well-recognized phenomenon in electron impact ionization sources for many decades, the effects of this process on the apparent precision of isotope ratio measurements has not been generally acknowledged in applications involving in vivo metabolic tracers.
引用
收藏
页码:481 / 486
页数:6
相关论文
共 22 条
[1]  
Beynon J. H., 1960, MASS SPECTROMETRY IT
[2]  
CAPRIOLI RM, 1972, BIOCH APPLICATIONS M, P735
[3]   EFFECT OF TOTAL PARENTERAL-NUTRITION ON FREE FATTY-ACID METABOLISM IN BURNED PATIENTS [J].
GOODENOUGH, RD ;
WOLFE, RR .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1984, 8 (04) :357-360
[4]   MEASUREMENT OF DENOVO HEPATIC LIPOGENESIS IN HUMANS USING STABLE ISOTOPES [J].
HELLERSTEIN, MK ;
CHRISTIANSEN, M ;
KAEMPFER, S ;
KLETKE, C ;
WU, K ;
REID, JS ;
MULLIGAN, K ;
HELLERSTEIN, NS ;
SHACKLETON, CHL .
JOURNAL OF CLINICAL INVESTIGATION, 1991, 87 (05) :1841-1852
[5]   WHOLE-BODY LIPOLYSIS AND TRIGLYCERIDE-FATTY ACID CYCLING IN CACHECTIC PATIENTS WITH ESOPHAGEAL CANCER [J].
KLEIN, S ;
WOLFE, RR .
JOURNAL OF CLINICAL INVESTIGATION, 1990, 86 (05) :1403-1408
[6]   MEASUREMENT OF TRIGLYCERIDE SYNTHESIS IN HUMANS USING DEUTERIUM-OXIDE AND ISOTOPE RATIO MASS-SPECTROMETRY [J].
LEITCH, CA ;
JONES, PJH .
BIOLOGICAL MASS SPECTROMETRY, 1991, 20 (06) :392-396
[7]   MEASUREMENT OF BIASES IN THE ELECTRON MULTIPLIER ION DETECTION SYSTEM OF A FINNIGAN-MAT MODEL 261 MASS-SPECTROMETER [J].
LOVERIDGE, WD .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 74 (2-3) :197-206
[8]   SELECTED ION MONITORING MASS-SPECTROMETRY - PARAMETERS AFFECTING QUANTITATIVE-DETERMINATION [J].
LOW, IA ;
LIU, RH ;
BARKER, SA ;
FISH, F ;
SETTINE, RL ;
PIOTROWSKI, EG ;
DAMERT, WC ;
LIU, JY .
BIOMEDICAL MASS SPECTROMETRY, 1985, 12 (11) :633-637
[9]   SYSTEMATIC-ERRORS IN GAS CHROMATOGRAPHY MASS SPECTROMETRY ISOTOPE RATIO MEASUREMENTS [J].
MATTHEWS, DE ;
HAYES, JM .
ANALYTICAL CHEMISTRY, 1976, 48 (09) :1375-1382
[10]  
Mook W. G., 1973, International Journal of Mass Spectrometry and Ion Physics, V12, P273, DOI 10.1016/0020-7381(73)80044-0