NOVEL MEMBRANELESS AMPEROMETRIC PEROXIDE BIOSENSOR BASED ON A TETRATHIAFULVALENE-P-TETRACYANOQUINODIMETHANE ELECTRODE

被引:29
作者
KORELL, U [1 ]
SPICHIGER, UE [1 ]
机构
[1] ETH ZURICH,DEPT ORGAN CHEM,CH-8092 ZURICH,SWITZERLAND
关键词
D O I
10.1021/ac00076a015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Amperometric biosensors for the detection of hydrogen peroxide are prepared by adsorbing peroxidase (POD, EC 1.11.1.7, lipophilized with caprylic aldehyde) to TTF-TCNQ/silicone oil paste electrodes. This is the first time a reductase is coupled to an organic conducting salt electrode. At -50 mV vs Ag/AgCl and pH 6.0, the current vs concentration function can be described by the enzyme kinetic Michaelis-Menten formalism. Stable signals are obtained within 10 s. The detection limit is typically in the low nanomolar range for H2O2. The enzyme stability under storage, standby, and various operation conditions is discussed.
引用
收藏
页码:510 / 515
页数:6
相关论文
共 26 条
[1]   AMPEROMETRIC ENZYME ELECTRODES [J].
ALBERY, WJ ;
BARTLETT, PN ;
CASS, AEG ;
EISENTHAL, R ;
HIGGINS, IJ .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES B-BIOLOGICAL SCIENCES, 1987, 316 (1176) :107-119
[2]   CARBON-FIBERS AS ELECTRODE MATERIALS FOR THE CONSTRUCTION OF PEROXIDASE-MODIFIED AMPEROMETRIC BIOSENSORS [J].
CSOREGI, E ;
GORTON, L ;
MARKOVARGA, G .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :59-70
[3]   ELECTRON-TRANSFER IN A NEW HIGHLY CONDUCTING DONOR-ACCEPTOR COMPLEX [J].
FERRARIS, J ;
WALATKA, V ;
PERLSTEI.JH ;
COWAN, DO .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1973, 95 (03) :948-949
[4]  
FILINOVSKY VY, 1984, COMPR TREAT, P9
[5]   AMPEROMETRIC BIOSENSORS BASED ON AN APPARENT DIRECT ELECTRON-TRANSFER BETWEEN ELECTRODES AND IMMOBILIZED PEROXIDASES - PLENARY LECTURE [J].
GORTON, L ;
JONSSONPETTERSSON, G ;
CSOREGI, E ;
JOHANSSON, K ;
DOMINGUEZ, E ;
MARKOVARGA, G .
ANALYST, 1992, 117 (08) :1235-1241
[6]   ELECTROCATALYTIC OXIDATION OF REDUCED NICOTINAMIDE COENZYMES BY GRAPHITE-ELECTRODES MODIFIED WITH AN ADSORBED PHENOXAZINIUM SALT, MELDOLA BLUE [J].
GORTON, L ;
TORSTENSSON, A ;
JAEGFELDT, H ;
JOHANSSON, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 161 (01) :103-120
[7]   FLOW-INJECTION AMPEROMETRIC SYSTEM FOR ENZYME-IMMUNOASSAY [J].
IVNITSKII, DM ;
SITDIKOV, RA ;
KUROCHKIN, VE .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :45-52
[8]  
IVNITSKII DM, 1985, BIOKHIM MIKROBIOL, V21, P821
[9]   AN ELECTROCHEMICAL SENSOR FOR HYDROGEN-PEROXIDE BASED ON PEROXIDASE ADSORBED ON A SPECTROGRAPHIC GRAPHITE ELECTRODE [J].
JONSSON, G ;
GORTON, L .
ELECTROANALYSIS, 1989, 1 (05) :465-468
[10]   CHEMICALLY MODIFIED CARBON PASTE ELECTRODES IN VOLTAMMETRIC ANALYSIS [J].
KALCHER, K .
ELECTROANALYSIS, 1990, 2 (06) :419-433