DOSE-RATE DISTRIBUTIONS AROUND CO-60, CS-137, AU-198, IR-192, AM-241, I-125 (MODELS 6702 AND 6711) BRACHYTHERAPY SOURCES AND THE NUCLIDE TC-99(M)

被引:38
作者
SAKELLIOU, L
SAKELLARIOU, K
SARIGIANNIS, K
ANGELOPOULOS, A
PERRIS, A
ZARRIS, G
机构
[1] INST NUCL TECHNOL, RADIAT PROTECT NCSR DEMOKRITOS, GR-15310 ATHENS, GREECE
[2] UNIV ATHENS, DEPT RADIOL, RADIAT PHYS UNIT, GR-11528 ATHENS, GREECE
关键词
D O I
10.1088/0031-9155/37/10/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Simple analytical functions derived from our point source Monte Carlo calculations on the combined attenuation and scatter factor, B exp(-mur), for Co-60, Cs-137 Au-198, Ir-192, Am-241, I-125 (models 6702 and 6711) brachytherapy sources and the nuclide Tc-99m, for water spherical geometries of radii R = 15 and 20 cm, are presented. Our results for the broadly used Co-60, Cs-137, Au-198 and Ir-192 brachytherapy sources can be compared directly and found in excellent agreement with the widely accepted data of Meisberger et al in the limited distance range for which the latter are valid. Our data, however, can be used with high accuracy outside this distance range. Many discrepancies observed among different data sets available in recent literature are. attributable to differences in geometries used. The results for the recently introduced Am-241 source are very dissimilar to those produced by any other currently used brachytherapy source. Dose rate distributions, based on the above simple functions, are proposed in accordance with the recommendations for calibration of the brachytherapy sources in terms of reference air kerma rate and were found to be in good agreement with data available in the literature. Our calculations for I-125 sources (models 6702 and 6711), provided that the characteristic x-rays from titanium encapsulation are taken into account, support recent experimental and theoretical dose rate distributions indicating that currently accepted values for I-125 may be overestimated.
引用
收藏
页码:1859 / 1872
页数:14
相关论文
共 40 条
[11]  
Hubbell J. H., 1975, Journal of Physical and Chemical Reference Data, V4, P471, DOI 10.1063/1.555523
[12]   PHOTON MASS ATTENUATION AND ENERGY-ABSORPTION COEFFICIENTS FROM 1 KEV TO 20 MEV [J].
HUBBELL, JH .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1982, 33 (11) :1269-1290
[13]   PHOTON MASS ATTENUATION AND MASS ENERGY-ABSORPTION COEFFICIENTS FOR H, C, N, O, AR, AND 7 MIXTURES FROM 0.1 KEV TO 20 MEV [J].
HUBBELL, JH .
RADIATION RESEARCH, 1977, 70 (01) :58-81
[14]   RELATIVISTIC ATOMIC FORM-FACTORS AND PHOTON COHERENT SCATTERING CROSS-SECTIONS [J].
HUBBELL, JH ;
OVERBO, I .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1979, 8 (01) :69-105
[15]   DOSE ANISOTROPY AROUND AN AU-198 SEED SOURCE [J].
JANI, SK ;
PENNINGTON, EC ;
KNOSP, BM .
MEDICAL PHYSICS, 1989, 16 (04) :632-636
[16]   COMPUTER DOSIMETRY OF IR-192 WIRE [J].
KLINE, RW ;
GILLIN, MT ;
GRIMM, DF ;
NIROOMANDRAD, A .
MEDICAL PHYSICS, 1985, 12 (05) :634-638
[17]   BRACHYTHERAPY BUILDUP FACTORS [J].
KORNELSEN, RO ;
YOUNG, MEJ .
BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (638) :136-136
[18]   TWO-DIMENSIONAL DOSE DISTRIBUTION OF I125 SEEDS [J].
LING, CC ;
SCHELL, MC ;
YORKE, ED ;
PALOS, BB ;
KUBIATOWICZ, DO .
MEDICAL PHYSICS, 1985, 12 (05) :652-655
[19]   THE INCORPORATION OF SPECIFIC TISSUE NUCLIDE ATTENUATION DATA INTO THE ANDERSON METHOD FOR PRODUCING BRACHYTHERAPY VOLUME DOSE HISTOGRAMS [J].
LOFT, SM ;
DALE, RG .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (11) :1519-1531
[20]   EFFECTIVE ATTENUATION IN WATER OF GAMMA RAYS OF GOLD 198 IRIDIUM 192 CESIUM 137 RADIUM 226 AND COBALT 60 [J].
MEISBERGER, LL ;
KELLER, RJ ;
SHALEK, RJ .
RADIOLOGY, 1968, 90 (05) :953-+