CORONARY-ARTERY DISEASE - FINDINGS WITH GRE MR-IMAGING AND TC-99M-METHOXYISOBUTYL-ISONITRILE SPECT DURING SIMULTANEOUS DOBUTAMINE STRESS

被引:38
作者
BAER, FM
VOTH, E
THEISSEN, P
SCHNEIDER, CA
SCHICHA, H
SECHTEM, U
机构
[1] UNIV COLOGNE, INTERNAL MED CLIN, D-50924 COLOGNE, GERMANY
[2] UNIV COLOGNE, NUCL MED CLIN, D-50924 COLOGNE, GERMANY
关键词
CORONARY VESSELS; STENOSIS OR OBSTRUCTION; MR; MYOCARDIUM; CT; ISCHEMIA;
D O I
10.1148/radiology.193.1.8090892
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: This study compared gradient-recalled echo (GRE) magnetic resonance (MR) imaging with technetium-99m-methoxyisobutyl isonitrile (MIB1) single photon emission computed tomography (SPECT) during the same dobutamine stress for the localization of coronary artery stenoses. MATERIALS AND METHODS: In 35 consecutive patients (28 men and seven women, aged 41-79 years) with angiographically documented coronary artery disease, corresponding GRE MR images and SPECT tomograms were acquired at rest and during dobutamine infusion and were evaluated for regional wall motion or perfusion abnormalities. RESULTS: Images in both examinations could be analyzed in 32 of 35 (91%) patients. Wall motion or perfusion abnormalities were observed in 27 of 32 (84%) GRE MR imaging and in 28 of 32 (87%) SPECT examinations. Sensitivity and specificity of dobutamine GRE MR imaging and dobutamine SPECT for the localization of left anterior descending coronary artery stenoses were 74% and 100% versus 70% and 100% for the combined left circumflex and right coronary artery perfusion territories. CONCLUSION: GRE MR imaging and SPECT have a high concordance with respect to the detection of a dobutamine-induced ischemic response.
引用
收藏
页码:203 / 209
页数:7
相关论文
共 24 条
  • [1] EFFECT OF PRIOR MYOCARDIAL-INFARCTION AND EXTENT AND LOCATION OF CORONARY-DISEASE ON ACCURACY OF EXERCISE ECHOCARDIOGRAPHY
    ARMSTRONG, WF
    ODONNELL, J
    RYAN, T
    FEIGENBAUM, H
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (03) : 531 - 538
  • [2] CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE
    ATKINSON, DJ
    EDELMAN, RR
    [J]. RADIOLOGY, 1991, 178 (02) : 357 - 360
  • [3] Baer F M, 1993, Int J Card Imaging, V9, P133, DOI 10.1007/BF01151437
  • [4] FEASIBILITY OF HIGH-DOSE DIPYRIDAMOLE-MAGNETIC RESONANCE IMAGING FOR DETECTION OF CORONARY-ARTERY DISEASE AND COMPARISON WITH CORONARY ANGIOGRAPHY
    BAER, FM
    SMOLARZ, K
    JUNGEHULSING, M
    THEISSEN, P
    SECHTEM, U
    SCHICHA, H
    HILGER, HH
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (01) : 51 - 56
  • [5] BAER FM, 1992, AM HEART J, V123, P636
  • [6] HIGH-DOSE DIPYRIDAMOLE ECHOCARDIOGRAPHY EARLY AFTER UNCOMPLICATED ACUTE MYOCARDIAL-INFARCTION - CORRELATION WITH EXERCISE TESTING AND CORONARY ANGIOGRAPHY
    BOLOGNESE, L
    SARASSO, G
    ARALDA, D
    BONGO, AS
    ROSSI, L
    ROSSI, P
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (02) : 357 - 363
  • [7] EXPERIMENTAL VALIDATION OF QUANTITATIVE CORONARY ARTERIOGRAPHY FOR DETERMINING PRESSURE-FLOW CHARACTERISTICS OF CORONARY STENOSIS
    GOULD, KL
    KELLEY, KO
    BOLSON, EL
    [J]. CIRCULATION, 1982, 66 (05) : 930 - 937
  • [8] HOFFKEN H, 1990, NUKLEARMED, V29, P135
  • [9] HOLMAN BL, 1984, J NUCL MED, V25, P1350
  • [10] QUANTITATIVE ROTATIONAL TOMOGRAPHY WITH TL-201 AND TC-99M 2-METHOXY-ISOBUTYL-ISONITRILE - A DIRECT COMPARISON IN NORMAL INDIVIDUALS AND PATIENTS WITH CORONARY-ARTERY DISEASE
    KAHN, JK
    MCGHIE, I
    AKERS, MS
    SILLS, MN
    FABER, TL
    KULKARNI, PV
    WILLERSON, JT
    CORBETT, JR
    [J]. CIRCULATION, 1989, 79 (06) : 1282 - 1293