QUANTITATIVE COMPARISONS OF IMAGE REGISTRATION TECHNIQUES BASED ON HIGH-RESOLUTION MRI OF THE BRAIN

被引:79
作者
STROTHER, SC
ANDERSON, JR
XU, XL
LIOW, JS
BONAR, DC
ROTTENBERG, DA
机构
[1] UNIV MINNESOTA,DEPT NEUROL,MINNEAPOLIS,MN 55455
[2] UNIV MINNESOTA,DEPT RADIOL,MINNEAPOLIS,MN 55455
关键词
IMAGE REGISTRATION; IMAGE QUALITY; EMISSION COMPUTED TOMOGRAPHY; MAGNETIC RESONANCE IMAGING;
D O I
10.1097/00004728-199411000-00021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: A variety of methods for matching intrasubject MRI-MRI, PET-PET, or MRI-PET image pairs have been proposed. Based on the rigid body transformations needed to align pairs of high-resolution MRI scans and/or simulated PET scans (derived from these MRI scans), we obtained general comparisons of four intrasubject image registration techniques: Talairach coordinates, head and hat, equivalent internal points, and ratio image uniformity. In addition, we obtained a comparison of stereotaxic Z frames with a customized head mold for MRI-MRI image pairs. Materials and Methods and Results: Each technique was quantitatively evaluated using the mean and maximum voxel registration errors for matched voxel pairs within the brain volumes being registered. Conclusion: We conclude that fiducial markers such as stereotaxic Z frames that are not rigidly fixed to a patient's skull are inaccurate compared with other registration techniques, Talairach coordinate transformations provide surprisingly good registration, and minimizing the variance of MRI-MRI, PET-PET, or MRI-PET ratio images provides significantly better registration than all other techniques tested. Registration optimization based on measurement of the similarity of spatial distributions of voxel values is superior to techniques that do not use such information.
引用
收藏
页码:954 / 962
页数:9
相关论文
共 40 条
[11]  
EVANS AC, 1989, P SOC PHOTO-OPT INS, V1092, P264
[12]   A STEREOTACTIC METHOD OF ANATOMICAL LOCALIZATION FOR POSITRON EMISSION TOMOGRAPHY [J].
FOX, PT ;
PERLMUTTER, JS ;
RAICHLE, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (01) :141-153
[13]   ENHANCED DETECTION OF FOCAL BRAIN RESPONSES USING INTERSUBJECT AVERAGING AND CHANGE-DISTRIBUTION ANALYSIS OF SUBTRACTED PET IMAGES [J].
FOX, PT ;
MINTUN, MA ;
REIMAN, EM ;
RAICHLE, ME .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (05) :642-653
[14]   LOCALIZATION IN PET IMAGES - DIRECT FITTING OF THE INTERCOMMISSURAL (AC-PC) LINE [J].
FRISTON, KJ ;
PASSINGHAM, RE ;
NUTT, JG ;
HEATHER, JD ;
SAWLE, GV ;
FRACKOWIAK, RSJ .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1989, 9 (05) :690-695
[15]   A COMPUTERIZED BRAIN ATLAS - CONSTRUCTION, ANATOMICAL CONTENT, AND SOME APPLICATIONS [J].
GREITZ, T ;
BOHM, C ;
HOLTE, S ;
ERIKSSON, L .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (01) :26-38
[16]  
HERHOLZ K, 1993, QUANTIFICATION BRAIN, P436
[17]  
HOH CK, 1993, J NUCL MED, V34, P2009
[18]   A NEW HEADHOLDER FOR PET, CT, AND NMR IMAGING [J].
KEARFOTT, KJ ;
ROTTENBERG, DA ;
KNOWLES, RJR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (06) :1217-1220
[19]  
LIN K, 1993, J NUCL MED, V5, pP183
[20]  
MAGIN JF, 1993, 1992 C REC IEEE NUCL, V2, P1262