STABILITY-INDICATING ASSAY FOR PIVMECILLINAM HYDROCHLORIDE AND PIVMECILLINAM HYDROCHLORIDE CAPSULES

被引:7
作者
HAGEL, RB
WAYSEK, EH
机构
[1] Quality Control Department, Hoffmann-La Roche Inc., Nutley, NJ 07110
来源
JOURNAL OF CHROMATOGRAPHY | 1979年 / 178卷 / 01期
关键词
D O I
10.1016/S0021-9673(00)89700-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-pressure liquid chromatographic assay was developed for pivmecillinam hydrochloride and pivmecillinam hydrochloride capsules. The method separates 5 reported degradation products and a number of esterified, related compounds. The accuracy of this method is comparable to the published UV assay, and the relative SD of a series of 6 replicate assays was better than .+-. 0.7%.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 8 条
[1]   STABILITY-INDICATING ASSAY FOR MECILLINAM USING HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
HAGEL, RB ;
WAYSEK, EH ;
HUMPHREY, D .
JOURNAL OF CHROMATOGRAPHY, 1979, 170 (02) :391-398
[2]  
HATTORI M, 1976, J TAKEDA RES LAB, V34, P159
[3]  
HATTORI M, 1977, CHEMOTHERAPY JPN, V25, P123
[4]  
LARSEN C, 1977, ARCH PHARM CHEMI SCI, V5, P1
[5]  
LARSEN C, 1977, ARCH PHARM CHEMI SCI, V5, P66
[6]  
ROHOLT K, 1977, J ANTIMICROB CHEMOTH, V3, P71, DOI 10.1093/jac/3.suppl_B.71
[7]  
UEMURA I, 1977, CHEMOTHERAPY, V25, P115
[8]  
WILLIAMS JD, 1977, J ANTIMICROB CHEM SB, V3, P1