ANALYSIS OF ALUMINUM IN PHARMACEUTICAL PRODUCTS BY POSTCOLUMN DERIVATIZATION ION CHROMATOGRAPHY

被引:15
作者
CARNEVALE, J [1 ]
JACKSON, PE [1 ]
机构
[1] WATERS CHROMAT DIV MILLIPORE,LANE COVE,NSW 2066,AUSTRALIA
关键词
D O I
10.1016/0021-9673(94)80229-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Aluminium can be determined in pharmaceutical products using a chromatographic method with a cation-exchange separation and fluorescence detection after post-column derivatization with 8-hydroxyquinoline-5-sulphonic acid. The method had a detection limit of less than 0.5 ng/ml and the aluminium peak response was linear up to at least 1200 ng/ml. Chromatographic reproducibility was approximately 1-3% over the concentration range of 50-1200 ng/ml. Sample preparation involved boiling in 0.05 M sulphuric acid for 5 min. The average recovery for Al spikes in the range 10-1200 ng/ml, from a variety of pharmaceutical samples, was 99% with an R.S.D. of 5%. No interferences from either sample matrix effects or transition metals were found and the results of the chromatographic method agreed well with those obtained by inductively coupled plasma atomic emission spectroscopy.
引用
收藏
页码:115 / 120
页数:6
相关论文
共 12 条
[1]   FLOW-INJECTION AND LIQUID-CHROMATOGRAPHIC DETERMINATION OF ALUMINUM BASED ON ITS FLUORIMETRIC REACTION WITH 8-HYDROXYQUINOLINE-5-SULFONIC ACID IN A MICELLAR MEDIUM [J].
ALONSO, JIG ;
GARCIA, AL ;
SANZMEDEL, A ;
GONZALEZ, EB ;
EBDON, L ;
JONES, P .
ANALYTICA CHIMICA ACTA, 1989, 225 (02) :339-350
[2]  
Clesceri LS., 1989, STANDARD METHODS EXA, V17
[3]  
Di Sciascio PW, 1992, CLIN BIOCHEM REV, V13, P60
[4]   EFFECT OF ALUMINUM SPECIATION ON FISH IN DILUTE ACIDIFIED WATERS [J].
DRISCOLL, CT ;
BAKER, JP ;
BISOGNI, JJ ;
SCHOFIELD, CL .
NATURE, 1980, 284 (5752) :161-164
[5]   THE APPLICATION OF FLUORESCENCE DETECTION TO THE DETERMINATION AND SPECIATION OF ALUMINUM IN SOIL SOLUTIONS BY ION CHROMATOGRAPHY [J].
GIBSON, JAE ;
WILLETT, IR .
COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 1991, 22 (13-14) :1303-1313
[6]   DETERMINATION OF TRACE AMOUNTS OF ALUMINUM BY ION CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
JONES, P ;
EBDON, L ;
WILLIAMS, T .
ANALYST, 1988, 113 (04) :641-644
[7]   DETERMINATION OF ALUMINUM IN THE HUMAN SERUM OF A DIALYSIS PATIENT BY ION-PAIR REVERSED-PHASE PARTITION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KANEKO, E ;
HOSHINO, H ;
YOTSUYANAGI, T ;
GUNJI, N ;
SATO, M ;
KIKUTA, T ;
YUASA, M .
ANALYTICAL CHEMISTRY, 1991, 63 (20) :2219-2222
[8]   THE CLINICAL BIOCHEMISTRY OF ALUMINUM [J].
KING, SW ;
SAVORY, J ;
WILLS, MR .
CRC CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 1981, 14 (01) :1-20
[9]   SIMULTANEOUS DETERMINATION OF CHROMIUM(III), ALUMINUM(III), AND IRON(II) IN TANNERY SLUDGE ACID-EXTRACTS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
LOPEZ, A ;
ROTUNNO, T ;
PALMISANO, F ;
PASSINO, R ;
TIRAVANTI, G ;
ZAMBONIN, PG .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1991, 25 (07) :1262-1266
[10]   FLUORESCENCE PROPERTIES OF METAL-COMPLEXES OF 8-HYDROXYQUINOLINE-5-SULFONIC ACID AND CHROMATOGRAPHIC APPLICATIONS [J].
SOROKA, K ;
VITHANAGE, RS ;
PHILLIPS, DA ;
WALKER, B ;
DASGUPTA, PK .
ANALYTICAL CHEMISTRY, 1987, 59 (04) :629-636