A METHOD FOR ANALYSIS OF THE LOCAL ATRIAL EVOKED-RESPONSE FOR DETERMINATION OF ATRIAL CAPTURE IN PERMANENT PACING SYSTEMS

被引:8
作者
CURTIS, AB [1 ]
MAAS, SM [1 ]
DOMIJAN, A [1 ]
KEIM, SG [1 ]
DURAN, A [1 ]
机构
[1] TELECTR PACING SYST,ENGLEWOOD,CO
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1991年 / 14卷 / 11期
关键词
PACEMAKERS; ATRIAL EVOKED RESPONSE; THRESHOLD; POLARIZATION ARTIFACT;
D O I
10.1111/j.1540-8159.1991.tb02731.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We developed a method for detection and analysis of the local atrial evoked response. Eleven patients undergoing permanent dual chamber pacemaker implantations for standard clinical indications were included in the study. Using a pacing system emulator, charge balancing using a variable triphasic stimulus waveform to reduce polarization artifact amplitude was performed first. This could not be completed in one patient because of a poor signal-to-noise ratio. Subsequent analysis of the local atrial evoked response in the remaining ten patients showed the typical signal to be a biphasic waveform with an initial negative deflection followed by a positive deflection nearly equal in amplitude. The mean amplitude of the atrial evoked response was 3.1 +/- 1.4 mV, while the intrinsic P wave amplitude in these same patients averaged 5.6 +/- 3.0 mV. The summed evoked response, a parameter that is directly proportional to the area of the signal, was used to determine atrial pacing threshold. The median atrial pacing threshold determined by the algorithm was 1.00 V. There was no instance of failure to detect loss of capture, nor was loss of capture inaccurately determined when there was still successful atrial pacing. Atrial capture in permanent pacing systems can thus be determined using an algorithm to record and analyze the local atrial evoked response. This method could potentially be useful in the automatic determination of atrial pacing threshold.
引用
收藏
页码:1576 / 1581
页数:6
相关论文
共 11 条
[1]   AUTODIAGNOSTIC PACEMAKER [J].
AUERBACH, AA ;
FURMAN, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (01) :58-68
[2]   MORPHOLOGY OF ENDOCARDIAL T-WAVES OF FUSION BEATS [J].
BOUTE, W ;
CALS, GLM ;
DENHEIJER, P ;
WITTKAMPF, FHM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11) :1693-1697
[3]   THE VENTRICULAR DEPOLARIZATION GRADIENT - EFFECTS OF EXERCISE, PACING RATE, EPINEPHRINE, AND INTRINSIC HEART-RATE CONTROL ON THE RIGHT VENTRICULAR EVOKED-RESPONSE [J].
CALLAGHAN, F ;
VOLLMANN, W ;
LIVINGSTON, A ;
BOVEJA, B ;
ABELS, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (07) :1115-1130
[4]   AUTOMATIC REDUCTION OF STIMULUS POLARIZATION ARTIFACT FOR ACCURATE EVALUATION OF VENTRICULAR EVOKED-RESPONSES [J].
CURTIS, AB ;
VANCE, F ;
MILLER, K .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (04) :529-537
[5]   RAPID ASSESSMENT OF RATE AND ANTIARRHYTHMIC DRUG EFFECT ON THE MYOCARDIUM USING ASYMMETRIC BIPHASIC PULSE STIMULATION [J].
FURUKAWA, T ;
HERSCOVICI, H ;
DESAI, T ;
SAMPSELL, R ;
NOGAMI, A ;
MOROE, K ;
ROZANSKI, JJ ;
LISTER, JW .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (01) :52-64
[6]   ATRIAL CAPTURE DETECTION WITH ENDOCARDIAL ELECTRODES [J].
LIVINGSTON, AR ;
CALLAGHAN, FJ ;
BYRD, CL ;
HEEMELS, JP ;
HOLLANDER, P ;
VANMECHELEN, R ;
CHAPPIN, JJML .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11) :1770-1776
[7]  
MUGICA J, 1973, CARDIAC PACING, P150
[8]  
Preston T A, 1974, Med Instrum, V8, P322
[9]  
PRESTON TA, 1973, CARDIAC PACING, P295
[10]  
RICKARDS AF, 1981, BRIT HEART J, V45, P56