MEASURING KLA WITH RANDOMLY PULSED DYNAMIC METHOD

被引:16
作者
GAUTHIER, L [1 ]
THIBAULT, J [1 ]
LEDUY, A [1 ]
机构
[1] LAVAL UNIV,DEPT CHEM ENGN,ST FOY G1K 7P4,QUEBEC,CANADA
关键词
OXYGEN TRANSFER COEFFICIENT; KLA; PULSED DYNAMIC METHOD; MECHANICALLY AGITATED VESSELS;
D O I
10.1002/bit.260370914
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This reports on the determination of the overall oxygen transfer coefficient in a mechanically agitated vessel using a randomly pulsed dynamic method. This method consists in exciting the system by randomly switching the inlet gas stream with air or nitrogen with an identical volumetric flow rate. A pseudo-random binary sequence was used. This procedure is routinely used in process control for the identification of system's transfer function. The pulsed dynamic method gives good reliability (as compared with the traditional gassing-out method) and reproducibility in water. However, further improvement is needed before it can be used to monitor on-line the k(L)a during a fermentation.
引用
收藏
页码:889 / 893
页数:5
相关论文
共 25 条
[1]   DYNAMIC MEASUREMENT OF VOLUMETRIC OXYGEN TRANSFER COEFFICIENT IN FERMENTATION SYSTEMS [J].
BANDYOPA.B ;
HUMPHREY, AE .
BIOTECHNOLOGY AND BIOENGINEERING, 1967, 9 (04) :533-&
[2]   MEASUREMENT OF KLA BY A GASSING-IN METHOD WITH OXYGEN-ENRICHED AIR [J].
CHANG, HN ;
HALARD, B ;
MOOYOUNG, M .
BIOTECHNOLOGY AND BIOENGINEERING, 1989, 34 (09) :1147-1157
[3]   Performance of agitated gas-liquid contactors [J].
Cooper, CM ;
Fernstrom, GA ;
Miller, SA .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1944, 36 :504-509
[4]  
DUNN IJ, 1975, J APPL CHEM BIOTECHN, V25, P707
[5]   INTERPRETATION OF STATIC AND DYNAMIC-RESPONSES OF A DISSOLVED-OXYGEN ELECTRODE IN VISCOUS BROTHS [J].
DUSSAP, CG ;
GROS, JB .
ANALYTICA CHIMICA ACTA, 1984, 163 (SEP) :151-160
[6]   MEASUREMENT OF AEROBIC BATCH CULTURE MAXIMUM SPECIFIC GROWTH-RATE AND RESPIRATION COEFFICIENT USING A DISSOLVED-OXYGEN PROBE [J].
HILL, GA ;
ROBINSON, CW .
BIOTECHNOLOGY AND BIOENGINEERING, 1974, 16 (04) :531-538
[7]  
KIM DJ, 1989, J CHEM TECHNOL BIOT, V45, P39
[8]   REASSESSMENT OF THE DYNAMIC KLA METHOD [J].
KOIZUMI, J ;
AIBA, S .
BIOTECHNOLOGY AND BIOENGINEERING, 1984, 26 (09) :1131-1133
[9]   DYNAMIC MEASUREMENT OF VOLUMETRIC MASS-TRANSFER COEFFICIENT IN AGITATED VESSELS - EFFECT OF START-UP PERIOD ON RESPONSE OF AN OXYGEN-ELECTRODE [J].
LINEK, V .
BIOTECHNOLOGY AND BIOENGINEERING, 1977, 19 (07) :983-1008
[10]   OXYGEN-ELECTRODE RESPONSE LAG INDUCED BY LIQUID-FILM RESISTANCE AGAINST OXYGEN-TRANSFER [J].
LINEK, V ;
VACEK, V .
BIOTECHNOLOGY AND BIOENGINEERING, 1976, 18 (11) :1537-1555