SKIN-SPARING REDUCTION EFFECTS OF THERMOPLASTICS USED FOR PATIENT IMMOBILIZATION IN HEAD AND NECK RADIOTHERAPY

被引:13
作者
FIORINO, C
CATTANEO, GM
DELVECCHIO, A
FUSCA, M
LONGOBARDI, B
SIGNOROTTO, P
CALANDRINO, R
机构
[1] Servizio di Fisica Sanitaria, Istituto Scientifteo-Ospedale San Raffaele, 20132 Milan
关键词
SKIN DOSE; BUILDUP; PLASTIC IMMOBILIZATION MASKS; HEAD AND NECK TUMORS;
D O I
10.1016/0167-8140(94)90468-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Skin-sparing benefits derived from the use of megavoltage photon beams can be strongly reduced when filters are inserted between the source and the patient. The use of plastic masks for immobilizing the patient is the most important cause of this reduction in head and neck treatments. The influence of thermoplastics, commercially available for patient immobilization systems (Orfit Raycast (Luxilon Ind. Co.), Posicast (Sinmed bv) and Optimold (WFR Aquaplast Corp.)), on the patient skin dose value has been investigated by using an NE2534 'Markus' chamber. Indicative measurements with moulded masks (carried out with 2-mm Orfit and 3.2-mm Optimold layers) show significant differences between masks moulded with the two thermoplastics.
引用
收藏
页码:267 / 270
页数:4
相关论文
共 15 条
[1]   STOPPING POWER DATA FOR HIGH-ENERGY PHOTON BEAMS [J].
ANDREO, P ;
BRAHME, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (08) :839-858
[2]  
CALANDRINO R, 1992, SEP M ESTRO MALM
[3]   VALIDITY OF TRANSITION-ZONE DOSIMETRY AT HIGH ATOMIC-NUMBER INTERFACES IN MEGAVOLTAGE PHOTON BEAMS [J].
DAS, IJ ;
KASE, KR ;
MEIGOONI, AS ;
KHAN, FM ;
WERNER, BL .
MEDICAL PHYSICS, 1990, 17 (01) :10-16
[4]   SKIN DOSE MEASUREMENTS FOR HEAD AND NECK RADIOTHERAPY [J].
FIORINO, C ;
CATTANEO, GM ;
DELVECCHIO, A ;
LONGOBARDI, B ;
SIGNOROTTO, P ;
CALANDRINO, R ;
FOSSATI, V ;
VOLTERRANI, F .
MEDICAL PHYSICS, 1992, 19 (05) :1263-1266
[5]  
GERBER RL, 1982, INT J RADIAT ONCOL, V8, P1460
[6]   MEASUREMENT OF DOSE IN THE BUILDUP REGION USING FIXED-SEPARATION PLANE-PARALLEL IONIZATION CHAMBERS [J].
GERBI, BJ ;
KHAN, FM .
MEDICAL PHYSICS, 1990, 17 (01) :17-26
[7]   THE POLARITY EFFECT FOR COMMERCIALLY AVAILABLE PLANE-PARALLEL IONIZATION CHAMBERS [J].
GERBI, BJ ;
KHAN, FM .
MEDICAL PHYSICS, 1987, 14 (02) :210-215
[8]   DETERMINATION OF BUILDUP REGION OVER-RESPONSE CORRECTIONS FOR A MARKUS-TYPE CHAMBER [J].
MELLENBERG, DE .
MEDICAL PHYSICS, 1990, 17 (06) :1041-1044
[9]   PLASTIC MATERIAL USED TO OPTIMIZE RADIOTHERAPY OF HEAD AND NECK TUMORS AND THE MAMMARY-CARCINOMA [J].
NIEWALD, M ;
LEHMANN, W ;
UHLMANN, U ;
SCHNABEL, K ;
LEETZ, HK .
RADIOTHERAPY AND ONCOLOGY, 1988, 11 (01) :55-63
[10]  
NILLSON B, 1986, MED PHYS, V13, P191