SAMPLE HANDLING AND PRETREATMENT USING FLOW-INJECTION ANALYSIS

被引:37
作者
CLARK, GD
WHITMAN, DA
CHRISTIAN, GD
RUZICKA, J
机构
[1] UNIV MINNESOTA,DEPT LAB MED & PATHOL,MINNEAPOLIS,MN 55455
[2] UNIV WASHINGTON,DEPT CHEM,SEATTLE,WA 98195
关键词
D O I
10.1080/10408349008050849
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow injection analysis (FIA) has been demonstrated to be an ideal tool for the handling and pretreatment of samples prior to their analysis. Sample handling may be as simple as the use of FIA for the introduction of the sample into a detector or as complicated as extraction of an analyte followed by back extraction prior to reaction and detection. In this survey, it is shown that FIA can encompass a large diversity of sample handling and pretreatment techniques. By employing FIA methods, one is able to significantly increase the sample throughput and, in many cases, increase the overall precision compared with batch style sampling, pretreatment, and analysis schemes. FIA sample handling and pretreatment techniques reviewed here include injection, dilution, membrane techniques, solvent extraction, and sorbent extraction/preconcentration. © 1990, Taylor & Francis Group, LLC. All rights reserved.
引用
收藏
页码:357 / 375
页数:19
相关论文
共 87 条
[1]   CONTINUOUS SOLVENT-EXTRACTION IN A CLOSED-LOOP SYSTEM [J].
ATALLAH, RH ;
RUZICKA, J ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1987, 59 (24) :2909-2914
[2]   DETERMINATION OF LOW PARTS PER BILLION LEVELS OF AMINES IN URINE BY LIQUID MEMBRANE SAMPLE CLEANUP DIRECTLY COUPLED TO A GAS-LIQUID CHROMATOGRAPH [J].
AUDUNSSON, G .
ANALYTICAL CHEMISTRY, 1988, 60 (13) :1340-1347
[3]   DESIGN AND EVALUATION OF A NEW PHASE SEPARATOR FOR LIQUID-LIQUID-EXTRACTION IN FLOW SYSTEMS [J].
BACKSTROM, K ;
DANIELSSON, LG ;
NORD, L .
ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) :43-49
[4]   DISPERSION IN PHASE SEPARATORS FOR FLOW-INJECTION EXTRACTION SYSTEMS [J].
BACKSTROM, K ;
DANIELSSON, LG ;
NORD, L .
ANALYTICA CHIMICA ACTA, 1986, 187 :255-269
[5]   PRECONCENTRATION AND MATRIX-ISOLATION OF HEAVY-METALS THROUGH A 2-STAGE SOLVENT-EXTRACTION IN A FLOW SYSTEM [J].
BENGTSSON, M ;
JOHANSSON, G .
ANALYTICA CHIMICA ACTA, 1984, 158 (02) :147-156
[6]   MERGING ZONES IN FLOW INJECTION ANALYSIS .1. DOUBLE PROPORTIONAL INJECTOR AND REAGENT CONSUMPTION [J].
BERGAMIN, H ;
ZAGATTO, EAG ;
KRUG, FJ ;
REIS, BF .
ANALYTICA CHIMICA ACTA, 1978, 101 (01) :17-23
[7]   NEW DEVICE FOR IMPROVING SENSITIVITY AND STABILIZATION IN FLOW-INJECTION ANALYSIS [J].
BERGAMIN, H ;
REIS, BF ;
ZAGATTO, EAG .
ANALYTICA CHIMICA ACTA, 1978, 97 (02) :427-431
[8]   SOLVENT-EXTRACTION IN CONTINUOUS-FLOW INJECTION ANALYSIS - DETERMINATION OF MOLYBDENUM IN PLANT MATERIAL [J].
BERGAMIN, H ;
MEDEIROS, JX ;
REIS, BF ;
ZAGATTO, EAG .
ANALYTICA CHIMICA ACTA, 1978, 101 (01) :9-16
[9]  
BERGAMIN H, 1980, ANAL CHIM ACTA, V117, P81, DOI 10.1016/0003-2670(80)87007-3
[10]  
BERHARDSON B, 1985, ANAL CHIM ACTA, V167, P111