AMPEROMETRIC FLOW-INJECTION ANALYSIS OF HYDRAZINE BY ELECTROCATALYTIC OXIDATION AT COBALT TETRAPHENYLPORPHYRIN MODIFIED ELECTRODE WITH HEAT-TREATMENT

被引:37
作者
HOU, WY [1 ]
JI, HM [1 ]
WANG, E [1 ]
机构
[1] CHINESE ACAD SCI,CHANGCHUN INST APPL CHEM,ELECTROANALYT CHEM LAB,CHANGCHUN 130022,PEOPLES R CHINA
关键词
D O I
10.1016/0039-9140(92)80048-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chemically modified electrodes prepared by treating the cobalt tetraphenylporphyrin modified glassy-carbon electrode at 750-degrees (HCME) are shown to catalyze the electrooxidation of hydrazine. The oxidation occurred at +0.63 V vs. Ag/AgCl (saturated potassium chloride) in pH 2.5 media. The catalytic response is evaluated with respect to solution pH, potential scan-rate, concentration dependence and flow-rate. The catalytic stability of the HCME is compared with that of the cobalt tetraphenylporphyrin adsorbed glassy-carbon electrode. The stability of the HCME was excellent in acidic solution and even in solutions containing organic solvent (50% CH3OH). When used as the sensing electrode in amperometric detection in flow-injection analysis, the HCME permitted sensitive detection of hydrazine at 0.5 V. The limit of detection was 0.1 ng. The linear range was from 50 ng to 2.4-mu-g. The method is very sensitive and selective.
引用
收藏
页码:45 / 50
页数:6
相关论文
共 29 条
[1]   ELECTROCATALYTIC REACTIONS ON CARBON-FIBER ELECTRODES MODIFIED BY HEMINE .2. ELECTRO-OXIDATION OF HYDRAZINE [J].
ANTONIADOU, S ;
JANNAKOUDAKIS, AD ;
THEODORIDOU, E .
SYNTHETIC METALS, 1989, 30 (03) :295-304
[2]  
AUTONIADOU S, 1989, SYNTHETIC MET, V32, P309
[3]   FLOW-INJECTION AMPEROMETRY OF CYSTEINE AND GLUTATHIONE AT AN ELECTRODE MODIFIED WITH A RUTHENIUM-CONTAINING INORGANIC FILM [J].
COX, JA ;
GRAY, TJ .
ELECTROANALYSIS, 1990, 2 (02) :107-111
[4]   STABLE MODIFIED ELECTRODES FOR FLOW-INJECTION AMPEROMETRY - APPLICATION TO THE DETERMINATION OF THIOCYANATE [J].
COX, JA ;
GRAY, T ;
KULKARNI, KR .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1710-1713
[5]   RESEARCH ON CHEMICALLY MODIFIED ELECTRODES - ELECTROCATALYTIC REDUCTION OF DIOXYGEN BY IRON TETRAPHENYLPORPHYRIN MODIFIED GLASSY-CARBON ELECTRODE WITH HEAT-TREATMENT [J].
DONG, SJ ;
JIANG, RZ .
BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1987, 91 (04) :479-484
[6]   INCREASED ELECTROCHEMICAL DETECTOR SENSITIVITY BY ELECTRODE SURFACE MODIFICATION [J].
GREGG, MR .
CHROMATOGRAPHIA, 1985, 20 (02) :129-133
[7]   ELECTROCATALYTIC AND ANALYTICAL RESPONSE OF COBALT PHTHALOCYANINE CONTAINING CARBON PASTE ELECTRODES TOWARD SULFHYDRYL COMPOUNDS [J].
HALBERT, MK ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1985, 57 (03) :591-595
[8]  
JI H, 1991, ANAL CHEM, V19, P976
[9]  
Kissinger P. T., 1984, LABORATORY TECHNIQUE, P611
[10]  
KORFHAGE KM, 1984, ANAL CHEM, V56, P1514, DOI 10.1021/ac00272a068