AMPEROMETRIC FLOW-INJECTION ANALYSIS OF HYDRAZINE BY ELECTROCATALYTIC OXIDATION AT COBALT TETRAPHENYLPORPHYRIN MODIFIED ELECTRODE WITH HEAT-TREATMENT

被引:37
作者
HOU, WY [1 ]
JI, HM [1 ]
WANG, E [1 ]
机构
[1] CHINESE ACAD SCI,CHANGCHUN INST APPL CHEM,ELECTROANALYT CHEM LAB,CHANGCHUN 130022,PEOPLES R CHINA
关键词
D O I
10.1016/0039-9140(92)80048-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chemically modified electrodes prepared by treating the cobalt tetraphenylporphyrin modified glassy-carbon electrode at 750-degrees (HCME) are shown to catalyze the electrooxidation of hydrazine. The oxidation occurred at +0.63 V vs. Ag/AgCl (saturated potassium chloride) in pH 2.5 media. The catalytic response is evaluated with respect to solution pH, potential scan-rate, concentration dependence and flow-rate. The catalytic stability of the HCME is compared with that of the cobalt tetraphenylporphyrin adsorbed glassy-carbon electrode. The stability of the HCME was excellent in acidic solution and even in solutions containing organic solvent (50% CH3OH). When used as the sensing electrode in amperometric detection in flow-injection analysis, the HCME permitted sensitive detection of hydrazine at 0.5 V. The limit of detection was 0.1 ng. The linear range was from 50 ng to 2.4-mu-g. The method is very sensitive and selective.
引用
收藏
页码:45 / 50
页数:6
相关论文
共 29 条
[11]   ELECTROCATALYSIS AND DETECTION OF AMINO-SUGARS, ALDITOLS, AND ACIDIC SUGARS AT A COPPER-CONTAINING CHEMICALLY MODIFIED ELECTRODE [J].
PRABHU, SV ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1989, 61 (20) :2258-2263
[12]   ENHANCEMENT OF LCEC RESPONSE BY USE OF ELECTROCHEMICALLY PRETREATED GLASSY-CARBON ELECTRODES [J].
RAVICHANDRAN, K ;
BALDWIN, RP .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1984, 7 (10) :2031-2050
[13]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF HYDRAZINES WITH ELECTROCHEMICALLY PRETREATED GLASSY-CARBON ELECTRODES [J].
RAVICHANDRAN, K ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1983, 55 (11) :1782-1786
[14]   PORPHYRIN STUDIES .5. THE METAL COMPLEX SALTS OF ALPHA,BETA,GAMMA,DELTA-TETRAPHENYLPORPHINE [J].
ROTHEMUND, P ;
MENOTTI, AR .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1948, 70 (05) :1808-1812
[15]   LIQUID-CHROMATOGRAPHY ELECTROCHEMICAL DETECTION OF CARBOHYDRATES AT A COBALT PHTHALOCYANINE CONTAINING CHEMICALLY MODIFIED ELECTRODE [J].
SANTOS, LM ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1987, 59 (14) :1766-1770
[16]   ELECTROCATALYTIC RESPONSE OF COBALT PHTHALOCYANINE CHEMICALLY MODIFIED ELECTRODES TOWARD OXALIC-ACID AND ALPHA-KETO ACIDS [J].
SANTOS, LM ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1986, 58 (04) :848-852
[17]  
SNYDER LR, 1979, INTRO MODERN LIQUID, P153
[18]   AMPEROMETRIC DETECTION OF NONELECTROACTIVE CATIONS IN FLOW SYSTEMS AT A CUPRIC HEXACYANOFERRATE ELECTRODE [J].
THOMSEN, KN ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1989, 61 (23) :2594-2598
[19]   LIQUID-CHROMATOGRAPHY AND ELECTROCHEMICAL DETECTION OF ALDITOLS AND ACIDIC SUGARS AT A COBALT PHTHALOCYANINE-CONTAINING CHEMICALLY MODIFIED ELECTRODE [J].
TOLBERT, AM ;
BALDWIN, RP .
ELECTROANALYSIS, 1989, 1 (05) :389-395
[20]   ELECTROCHEMICAL DETECTION OF RIBONUCLEOTIDES AT A CARBON PASTE ELECTRODE CONTAINING COBALT PHTHALOCYANINE [J].
TOLBERT, AM ;
BALDWIN, RP ;
SANTOS, LM .
ANALYTICAL LETTERS, 1989, 22 (03) :683-702