THE EFFECT ON MINIMUM TUMOR DOSE OF RESTRICTING TARGET-DOSE INHOMOGENEITY IN OPTIMIZED 3-DIMENSIONAL TREATMENT OF LUNG-CANCER

被引:25
作者
LANGER, M
KIJEWSKI, P
BROWN, R
HA, C
机构
[1] JOINT CTR RADIAT THERAPY,BOSTON,MA 02115
[2] SOFTBRIDGE GRP,CAMBRIDGE,MA
关键词
LUNG CANCER; OPTIMIZED 3-DIMENSIONAL TREATMENT; TARGET DOSE; COMPUTER CONTROLLED RADIOTHERAPY;
D O I
10.1016/0167-8140(91)90049-M
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
An examination was made of the effect upon the minimum tumor dose of a limit placed on the variation of dose across target. If the required level of target dose uniformity is slightly relaxed, a substantial improvement in the minimum tumor dose might appear. It was conjectured that this effect could be seen with treatments optimally planned and evaluated in three-dimensions. A model of advanced carcinoma of the lung treated with a computer controlled accelerator was used to test this hypothesis. A mathematical program for optimizing beam weights was used to determine the largest minimum tumor dose possible. In the six cases tested, a minimum tumor dose of > 80 Gy could be delivered if a 20% inhomogeneity limit was accepted. The minimum tumor dose fell to the range 44-64 Gy when the inhomogeneity limit was tightened to 13-17%. The results imply a need to examine the choice of a required level of dose uniformity from the range of values suggested in the 2-dimensional planning literature. If a strict bound-on-dose uniformity is preserved, mechanisms - such as formal optimization - which can reduce target dose inhomogeneity will be valuable.
引用
收藏
页码:245 / 256
页数:12
相关论文
共 30 条
  • [11] OPTIMIZATION OF BEAM WEIGHTS UNDER DOSE-VOLUME RESTRICTIONS
    LANGER, M
    LEONG, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (08): : 1255 - 1260
  • [12] LARGE-SCALE OPTIMIZATION OF BEAM WEIGHTS UNDER DOSE-VOLUME RESTRICTIONS
    LANGER, M
    BROWN, R
    URIE, M
    LEONG, J
    STRACHER, M
    SHAPIRO, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (04): : 887 - 893
  • [13] LANGER M, IN PRESS INT J RAD O
  • [14] SOFTWARE FOR LINEAR AND NON-LINEAR OPTIMIZATION IN EXTERNAL RADIOTHERAPY
    LEGRAS, J
    LEGRAS, B
    LAMBERT, JP
    [J]. COMPUTER PROGRAMS IN BIOMEDICINE, 1982, 15 (03): : 233 - 242
  • [15] AUTOMATIC VARIATION OF FIELD SIZE AND DOSE-RATE IN ROTATION THERAPY
    MANTEL, J
    PERRY, H
    WEINKAM, JJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1977, 2 (7-8): : 697 - 704
  • [16] MARSTEN R, 1985, USERS MANUAL ZOOM XM
  • [17] OPTIMIZATION OF EXTERNAL BEAM RADIATION-THERAPY
    MCDONALD, SC
    RUBIN, P
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1977, 2 (3-4): : 307 - 317
  • [18] RANDOM SAMPLING FOR EVALUATING TREATMENT PLANS
    NIEMIERKO, A
    GOITEIN, M
    [J]. MEDICAL PHYSICS, 1990, 17 (05) : 753 - 762
  • [19] THE INFLUENCE OF THE SIZE OF THE GRID USED FOR DOSE CALCULATION ON THE ACCURACY OF DOSE ESTIMATION
    NIEMIERKO, A
    GOITEIN, M
    [J]. MEDICAL PHYSICS, 1989, 16 (02) : 239 - 247
  • [20] PEREZ CA, 1980, CANCER, V45, P2744, DOI 10.1002/1097-0142(19800601)45:11<2744::AID-CNCR2820451108>3.0.CO