Objective: It has recently been suggested that conductance catheter parallel conductance (alpha V-c) is a function of left ventricular volume. To confirm this, alpha V-c was measured in this study over a wide range of steady state volumes. In addition, conductance derived volumes were compared to those obtained by radionuclide angiography to determine if the conductance catheter can be used to measure absolute left ventricular volume accurately in the intact dog heart. Methods: Seven dogs were anaesthetised and instrumented with left ventricular conductance and pressure tip catheters, a flow through rho cuvette to continually measure blood resistance, a thermodilution catheter, and a venous catheter for volume infusion/withdrawal. Conductance and angiographic data were acquired at 8(SD 1) variably loaded states. Parallel conductance was measured twice at each state using a saline dilution technique and a new non-linear algorithm that allows variability in the observations of both maximum and minimum conductance volumes. Results: The mean value of alpha V-c was 89.1(18.0) ml (71.8 to 111.3 ml) with a mean within-animal coefficient of variation of 7.3(3.4)%. Multiple linear regression using dummy variables to account for the large interanimal variability did not reveal any relationship between alpha V-c and either maximum or minimum left ventricular volume. Furthermore, no difference was found when alpha V-c values measured at the lowest and highest loading levels in each dog were compared. Linear regression showed good agreement between conductance and radionuclide derived end diastolic volumes (slope=0.94, R=0.9, p<0.0001). Conclusions: While alpha V-c varies between animals, it remains constant within any given animal over a broad range of left ventricular volumes. Thus the conductance catheter can provide reliable absolute left ventricular volume measurements under steady state conditions.
引用
收藏
页码:252 / 258
页数:7
相关论文
共 25 条
  • [1] SIMULTANEOUS CONDUCTANCE CATHETER AND DIMENSION ASSESSMENT OF LEFT-VENTRICLE VOLUME IN THE INTACT ANIMAL
    APPLEGATE, RJ
    CHENG, CP
    LITTLE, WC
    [J]. CIRCULATION, 1990, 81 (02) : 638 - 648
  • [2] CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER
    BAAN, J
    VANDERVELDE, ET
    DEBRUIN, HG
    SMEENK, GJ
    KOOPS, J
    VANDIJK, AD
    TEMMERMAN, D
    SENDEN, J
    BUIS, B
    [J]. CIRCULATION, 1984, 70 (05) : 812 - 823
  • [3] Baan J., 1989, Automedica, V11, P357
  • [4] CONTINUOUS STROKE VOLUME AND CARDIAC-OUTPUT FROM INTRAVENTRICULAR DIMENSIONS OBTAINED WITH IMPEDANCE CATHETER
    BAAN, J
    JONG, TTA
    KERKHOF, PLM
    MOENE, RJ
    VANDIJK, AD
    VANDERVELDE, ET
    KOOPS, J
    [J]. CARDIOVASCULAR RESEARCH, 1981, 15 (06) : 328 - 334
  • [5] LEFT-VENTRICULAR VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN INTACT DOGS - PARALLEL CONDUCTANCE VOLUME DEPENDS ON LEFT-VENTRICULAR SIZE
    BOLTWOOD, CM
    APPLEYARD, RF
    GLANTZ, SA
    [J]. CIRCULATION, 1989, 80 (05) : 1360 - 1377
  • [6] ACCURACY OF VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN ISOLATED, EJECTING CANINE HEARTS
    BURKHOFF, D
    VANDERVELDE, E
    KASS, D
    BAAN, J
    MAUGHAN, WL
    SAGAWA, K
    [J]. CIRCULATION, 1985, 72 (02) : 440 - 447
  • [7] DETECTION OF LEFT-VENTRICULAR REGIONAL MYOCARDIAL ISCHEMIA IN DOGS BY INTRAVENTRICULAR CONDUCTANCE CATHETER
    FISCHER, EIC
    SPINELLI, JC
    WILLSHAW, P
    CROTTOGINI, AJ
    DEFORTEZA, E
    CLAVIN, O
    VALENTINUZZI, ME
    PICHEL, RH
    [J]. CARDIOVASCULAR RESEARCH, 1988, 22 (03) : 185 - 192
  • [8] A METHOD TO ESTIMATE THE POINT AT WHICH 2 LINES INTERSECT FROM NOISY DATA
    GLANTZ, SA
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 259 (04): : H1305 - H1306
  • [9] GLANTZ SA, 1990, PRIMER APPLIED REGRE
  • [10] USE OF A CONDUCTANCE (VOLUME) CATHETER AND TRANSIENT INFERIOR VENA-CAVAL OCCLUSION FOR RAPID-DETERMINATION OF PRESSURE-VOLUME RELATIONSHIPS IN MAN
    KASS, DA
    MIDEI, M
    GRAVES, W
    BRINKER, JA
    MAUGHAN, WL
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1988, 15 (03): : 192 - 202