BIOSENSOR FOR CONTINUOUS GLUCOSE MONITORING

被引:29
作者
ATANASOV, P [1 ]
WILKINS, E [1 ]
机构
[1] UNIV NEW MEXICO, DEPT CHEM & NUCL ENGN, ALBUQUERQUE, NM 87131 USA
关键词
AMPEROMETRIC GLUCOSE BIOSENSOR; OXYGEN ELECTRODE; RECHARGEABLE SENSOR; CONTINUOUS GLUCOSE MONITORING;
D O I
10.1002/bit.260430310
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A potentially implantable glucose biosensor for continuous monitoring of glucose levels in diabetic patients has been developed. The glucose biosensor is based on an amperometric oxygen electrode and glucose oxidase immobilized on carbon powder held in a form of a liquid suspension. The enzyme material can be replaced (the sensor recharged) without sensor disassembly. Recharging of the biosensor is achieved by injecting fresh immobilized enzyme into the sensor using a septum. Diffusion membranes made of silastic latex-rubber coatings over a microporous polycarbonate membrane are used. Calibration curves of the amperometric signal show linearity over a wide range of glucose concentrations-up to 500 mg/dL (28 mM), covering hypoglycemic, normoglycemic, and hyperglycemic conditions. Preliminary in vitro studies of the biosensor show stable performance during several recharge cycles (of 14 days each) over a period of 4 months. (C) 1994 John Wiley & Sons, Inc.
引用
收藏
页码:262 / 266
页数:5
相关论文
共 34 条
[1]   APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS [J].
ARMOUR, JC ;
LUCISANO, JY ;
MCKEAN, BD ;
GOUGH, DA .
DIABETES, 1990, 39 (12) :1519-1526
[2]   GLUCOSE BIOSENSOR BASED ON OXYGEN-ELECTRODE .1. SILASTIC COATED POLYCARBONATE MEMBRANES FOR BIOSENSOR APPLICATION [J].
ATANASOV, P ;
WILKINS, E .
ANALYTICAL LETTERS, 1993, 26 (08) :1587-1612
[3]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[4]   ENZYME PACKED-BED SYSTEM FOR THE ONLINE MEASUREMENT OF GLUCOSE, GLUTAMATE, AND LACTATE IN BRAIN MICRODIALYSATE [J].
BOUTELLE, MG ;
FELLOWS, LK ;
COOK, C .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1790-1794
[5]   INVIVO MEASUREMENT OF SUBCUTANEOUS GLUCOSE-CONCENTRATIONS WITH AN ENZYMATIC GLUCOSE SENSOR AND A WICK METHOD [J].
BRUCKEL, J ;
KERNER, W ;
ZIER, H ;
STEINBACH, G ;
PFEIFFER, EF .
KLINISCHE WOCHENSCHRIFT, 1989, 67 (09) :491-495
[6]  
Buchwald H, 1992, ASAIO J, V38, P772, DOI 10.1097/00002480-199210000-00005
[7]   AMPEROMETRIC NEEDLE-TYPE GLUCOSE SENSOR BASED ON A MODIFIED PLATINUM-ELECTRODE WITH DIMINISHED RESPONSE TO INTERFERING MATERIALS [J].
CHEN, CY ;
GOTOH, M ;
MAKINO, H ;
SU, YC ;
TAMIYA, E ;
KARUBE, I .
ANALYTICA CHIMICA ACTA, 1992, 265 (01) :5-14
[8]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[9]   IMPLANTED ELECTROENZYMATIC GLUCOSE SENSORS [J].
CLARK, LC ;
DUGGAN, CA .
DIABETES CARE, 1982, 5 (03) :174-180
[10]   THE DEVELOPMENT AND APPLICATION OF BIOSENSING DEVICES FOR BIOREACTOR MONITORING AND CONTROL [J].
CLARKE, DJ ;
CALDER, MR ;
CARR, RJG ;
BLAKECOLEMAN, BC ;
MOODY, SC ;
COLLINGE, TA .
BIOSENSORS, 1985, 1 (03) :213-320