CROSS-FLOW ULTRAFILTRATION OF PROTEINS THROUGH ASYMMETRIC POLYSULFONIC MEMBRANES .1. RETENTION CURVES AND PORE-SIZE DISTRIBUTIONS

被引:15
作者
PRADANOS, P [1 ]
HERNANDEZ, A [1 ]
机构
[1] UNIV VALLADOLID,FAC CIENCIAS,DPTO FIS APLICADA 2,E-47071 VALLADOLID,SPAIN
关键词
CROSS-FLOW ULTRAFILTRATION; POLYSULFONIC MEMBRANES; PROTEINS; CONCENTRATION-POLARIZATION; PORE SIZE DISTRIBUTIONS;
D O I
10.1002/bit.260470602
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Flux and retention of 0.1% w/w aqueous solutio ns of several proteins [lysozyme, pepsin, bovine serum albumin (BSA), lipase, and gamma-globulin] with molecular weights of 14.6, 36, 67, 80, and 150 kDa are studied when they are tangentially filtered, with transmembrane pressure differences until 1 MPa and circulation velocities in the retentate loop from 0.04 to 1.98 m/s (laminar regime), through two asymmetric polysulfone commercial membranes (E-100 with a nominal pore size of 0.01 mu m and E-500 with a nominal pore size of 0.04 mu m). Results are analyzed with the film theory for the concentration-polarization phenomenon, obtaining the mass transfer coefficient along with the apparent and true retention coefficients for the cell used, as a function of the feed circulation velocity and the molecular weight of the solute. The standard retention curves lead to pore size distributions differing from the nominal ones. These differences can be attributed to the modifications of the membranes when they are in operational conditions, probably due to protein adsorption. (C) 1995 John Wiley & Sons, Inc.
引用
收藏
页码:617 / 625
页数:9
相关论文
共 26 条
[1]   PROTEIN ULTRAFILTRATION - EXPERIMENTAL STUDY [J].
BELLUCCI, F ;
DRIOLI, E ;
SCARDI, V .
JOURNAL OF APPLIED POLYMER SCIENCE, 1975, 19 (06) :1639-1647
[2]   THE INFLUENCE OF MOLECULAR MASS OF POLY(VINYL CHLORIDE) ON THE STRUCTURE AND TRANSPORT CHARACTERISTICS OF ULTRAFILTRATION MEMBRANES [J].
BODZEK, M ;
KONIECZNY, K .
JOURNAL OF MEMBRANE SCIENCE, 1991, 61 :131-156
[3]   PROPERTIES OF MICROFILTRATION MEMBRANES - FLUX LOSS DURING CONSTANT PRESSURE PERMEATION OF BOVINE SERUM-ALBUMIN [J].
BOWEN, WR ;
GAN, Q .
BIOTECHNOLOGY AND BIOENGINEERING, 1991, 38 (07) :688-696
[4]   ENZYME INACTIVATION WITH SHEARING [J].
CHARM, SE ;
WONG, BL .
BIOTECHNOLOGY AND BIOENGINEERING, 1970, 12 (06) :1103-&
[5]  
Cheryan M., 1986, ULTRAFILTRATION HDB
[6]   MASS-TRANSFER IN THE MEMBRANE CONCENTRATION POLARIZATION LAYER UNDER TURBULENT CROSS FLOW .1. CRITICAL LITERATURE-REVIEW AND ADAPTATION OF EXISTING SHERWOOD CORRELATIONS TO MEMBRANE OPERATIONS [J].
GEKAS, V ;
HALLSTROM, B .
JOURNAL OF MEMBRANE SCIENCE, 1987, 30 (02) :153-170
[7]  
GEKAS V, 1993, ULTRFILTRATION MEMBR
[8]   PROTEIN TYPE EFFECTS ON STEADY-STATE CROSS-FLOW MEMBRANE ULTRAFILTRATION FLUXES AND PROTEIN TRANSMISSION [J].
GRUND, G ;
ROBINSON, CW ;
GLICK, BR .
JOURNAL OF MEMBRANE SCIENCE, 1992, 70 (2-3) :177-192
[9]  
HWANG ST, 1984, TECHNIQUES CHEM, V7
[10]   CONCENTRATION POLARIZATION IN A REVERSE-OSMOSIS TEST CELL [J].
JONSSON, G ;
BOESEN, CE .
DESALINATION, 1977, 21 (01) :1-10