SIMPLE AND ACCURATE CALIBRATION TECHNIQUE FOR MEASURING GAMMA-RAY ENERGIES AND GE(LI)DETECTOR LINEARITY

被引:25
作者
STRAUSS, MG
LENKSZUS, FR
EICHHOLZ, JJ
机构
[1] Argonne National Laboratory, Argonne
来源
NUCLEAR INSTRUMENTS & METHODS | 1969年 / 76卷 / 02期
关键词
D O I
10.1016/0029-554X(69)90030-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A technique for precise calibration of Ge(Li) γ-ray spectrometers, which is particularly useful in studies of decay schemes, has been developed. The differential response of a multichannel analyzer is measured with a sliding pulse generator whose incremental nonlinearity is 0.005-0.01%. The integral of this response with respect to counts is a linear function of energy. With the use of two known γ-ray lines the calibration constant in counts/keV, and in turn, the energies corresponding to unknown γ-ray peaks can be determined. The technique is simple, fast and virtually automatic. The method was evaluated by measuring γ-ray energies (0.27-2.75 MeV) from ten sources. The results obtained agree with published values to within the measurement uncertainty of 40-110 eV. The accuracy of the technique depends on the linearity of the sliding pulser and the Ge(Li) detector. From a spectrum of 66Ga, measured energy intervals of 2m0c2 were examined as a function of γ-ray energy. The standard deviation of the eight 2m0c2 intervals was only 0.08 keV. It is therefore concluded that between 1 and 5 MeV the incremental non-linearity of the coaxial Ge(Li) detector is less than ±0.1 keV. Measurement uncertainties due to errors in the calibration standards, peak location, and the number of counts/channel in the differential response are discussed. © 1969.
引用
收藏
页码:285 / &
相关论文
共 16 条
[1]   MEASUREMENT OF HIGH-ENERGY GAMMA-RAYS WITH GE(LI) DETECTORS [J].
BERG, RE ;
KASHY, E .
NUCLEAR INSTRUMENTS & METHODS, 1966, 39 (01) :169-&
[2]   MEASUREMENT OF SOME GAMMA-RAY ENERGIES SUITABLE FOR ROUTINE ENERGY CALIBRATION [J].
BLACK, WW ;
HEATH, RL .
NUCLEAR PHYSICS A, 1967, A 90 (03) :650-&
[3]   A PRECISION COMPUTER-CONTROLLED PULSE GENERATOR AND ITS APPLICATION [J].
BLACK, WW .
NUCLEAR INSTRUMENTS & METHODS, 1967, 53 (02) :249-&
[4]   STABLE 1-PF CHARGE INJECTION CAPACITOR FOR NUCLEAR PULSE PREAMPLIFIERS [J].
BRENNER, R .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1969, 40 (08) :1011-&
[5]   CALIBRATION OF A GE(LI) GAMMA-RAY SPECTROMETER FOR ENERGY AND RELATIVE INTENSITY MEASUREMENTS [J].
DONNELLY, DP ;
BAER, HW ;
REIDY, JJ ;
WIEDENBECK, ML .
NUCLEAR INSTRUMENTS & METHODS, 1967, 57 (02) :219-+
[6]   ULTRA LINEAR RAMP GENERATOR FOR SLIDING PULSERS [J].
EICHHOLZ, JJ ;
STRAUSS, MG ;
BANNON, RW .
NUCLEAR INSTRUMENTS & METHODS, 1969, 76 (02) :278-&
[7]   A DIGITALLY-CONTROLLED PRECISION PULSER [J].
GREENBLATT, J ;
KUCHELA, KS ;
SHERMAN, NK .
NUCLEAR INSTRUMENTS & METHODS, 1967, 49 (01) :86-+
[8]   PRECISE DETERMINATIONS OF HIGH-ENERGY GAMMA RAYS AND ERRORS IN PAIR-PEAK METHOD [J].
GUNNINK, R ;
MEYER, RA ;
NIDAY, JB ;
ANDERSON, RP .
NUCLEAR INSTRUMENTS & METHODS, 1968, 65 (01) :26-&
[9]   ARMSPAN - ARGONNE MULTICHANNEL STORED PROGRAM ANALYZER [J].
LENKSZUS, FR ;
STRAUSS, MG .
NUCLEAR INSTRUMENTS & METHODS, 1969, 72 (02) :188-&
[10]   LINEARITY OF A GE(LI) DETECTOR IN RANGE 0.5 TO 10 MEV [J].
LEVY, AJ ;
RITTER, RC .
NUCLEAR INSTRUMENTS & METHODS, 1967, 49 (02) :359-&