THE DEVELOPMENT OF A MICROWAVE FLUID-BED PROCESSOR .1. CONSTRUCTION AND QUALIFICATION OF A PROTOTYPE LABORATORY UNIT

被引:10
作者
DOELLING, MK [1 ]
JONES, DM [1 ]
SMITH, RA [1 ]
NASH, RA [1 ]
机构
[1] ST JOHNS UNIV,COLL PHARM & ALLIED HLTH PROFESS,JAMAICA,NY 11439
关键词
MICROWAVE DRYER; FLUID-BED DRYER; PROCESS EQUIPMENT VALIDATION;
D O I
10.1023/A:1015875300053
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The static bed- and planetary-type microwave dryers currently available to process pharmaceutical materials are not designed to use hot-air fluidization for the purpose of maximizing microwave energy inputs and particle drying. To take advantage of the benefits offered by fluidization, a 1-kg Uni-Gatt laboratory fluid bed processor was modified to support microwave-assisted fluid bed drying of several representative pharmaceutical granulations. The construction, design features, and validation of this new microwave fluid bed processor are presented.
引用
收藏
页码:1487 / 1492
页数:6
相关论文
共 22 条
[1]  
AULTON ME, 1978, MANUFACT CHEM AE DEC
[2]   BATCH PRODUCTION OF PHARMACEUTICAL GRANULATIONS IN A FLUIDIZED-BED .3. BINDER DILUTION EFFECTS ON GRANULATION [J].
DAVIES, WL ;
GLOOR, WT .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1973, 62 (01) :170-171
[3]   BATCH PRODUCTION OF PHARMACEUTICAL GRANULATIONS IN A FLUIDIZED BED .1. EFFECTS OF PROCESS VARIABLES ON PHYSICAL PROPERTIES OF FINAL GRANULATION [J].
DAVIES, WL ;
GLOOR, WT .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1971, 60 (12) :1869-&
[5]  
DESMET P, 1989, MANUFACT CHEM MAR
[6]  
DOYLE C, 1987, MANUFACT CHEM FEB
[7]  
GORE A Y, 1985, Pharmaceutical Technology, V9, P114
[8]  
HUBBLE PE, 1982, CHEM ENG-NEW YORK, V89, P125
[9]  
JONES DM, 1985, PHARM TECH, V9, P30
[10]  
KOBLITZ T, 1986, PHARM TECH, V10, P32