2-SAMPLE HEMODIALYSIS UREA KINETIC MODELING - VALIDATION OF THE METHOD

被引:9
作者
BUUR, T [1 ]
机构
[1] ST JAMES UNIV HOSP,DEPT RENAL MED,LEEDS LS9 7TF,W YORKSHIRE,ENGLAND
来源
NEPHRON | 1995年 / 69卷 / 01期
关键词
DIALYSIS; ADEQUACY; HEMODIALYSIS; PROTEIN CATABOLISM; UREA KINETIC MODELING; COMPUTATION;
D O I
10.1159/000188359
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Urea kinetic modeling (UKM) by a two-sample method (UKM(2)) was compared with the classical three-sample method (UKM(3)) and direct quantification. Assurinng the patient to be in a weekly steady state and using an approximate treatment schedule, UKM2 can compute urea generation rate (G), distribution volume (V), Kt/V, and normalized protein catabolic rate (NPCR). Twenty-three stable patients were examined. The results obtained by UKM(2) and UKM(3) differed little (G -4.2%, V -1.0%, Kt/V 0.9%, NPCR -2.7%), and the correlations between them were high (r greater than or equal to 0.96). The differences between UKM(2) and direct quantification were greater, but also highly correlated. G determined midweekly by UKM(2) was highly correlated with G found directly from 1-week collection of dialysate and urine (r=0.96). Repeating analysis over a 5-week period, the results obtained by UKM(2) varied no more than those obtained by UKM(3) (around 8% for all four kinetic variables). In conclusion, UKM(2) produces reliable results requiring less data to be entered than using UKM(3).
引用
收藏
页码:49 / 53
页数:5
相关论文
共 18 条
[1]   DIAKIN - AN INTEGRATED PROGRAM PACKAGE FOR HEMODIALYSIS KINETICS [J].
BUUR, T .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1990, 31 (3-4) :243-254
[2]   ACCURACY OF HEMODIALYSIS UREA KINETIC MODELING - COMPARISON OF DIFFERENT MODELS [J].
BUUR, T ;
LARSSON, R .
NEPHRON, 1991, 59 (03) :358-363
[3]   PRECISION OF HEMODIALYSIS UREA KINETIC MODELING - EMPIRICAL-DATA AND MONTE-CARLO SIMULATION [J].
BUUR, T .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1991, 35 (01) :25-34
[4]   COMPARISON BETWEEN 3 MATHEMATICAL-MODELS OF KT/V [J].
CALZAVARA, P ;
VIANELLO, A ;
DAPORTO, A ;
GATTI, PL ;
BERTOLONE, G ;
CAENARO, G ;
ROSA, CD .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1988, 11 (02) :107-110
[5]  
Daugirdas J T, 1989, ASAIO Trans, V35, P336, DOI 10.1097/00002480-198907000-00052
[6]  
DEPNER TA, 1989, T AM SOC ART INT ORG, V35, P499
[7]  
Depner TA., 1991, PRESCRIBING HEMODIAL, V2nd Ed.
[8]  
ELLIS PW, 1984, T AM SOC ART INT ORG, V30, P60
[9]  
Farrell PC, 1977, 2ND T AUSTR C HEAT M, P29
[10]   UREA KINETIC MODELING BY PARTIAL DIALYSATE COLLECTION [J].
GARRED, LJ ;
RITTAU, M ;
MCCREADY, W ;
CANAUD, B .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1989, 12 (02) :96-102