EFFECT OF GAS-PRESSURE ON THE COLLISIONAL LINE-WIDTH AND LINE SHIFT IN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY

被引:8
作者
CHANG, JC
OHAVER, TC
机构
[1] Department of Chemistry and Biochemistry, University of Maryland, College Park
关键词
ATOMIC ABSORPTION SPECTROMETRY; CONTINUUM; LINE WIDTH; PRESSURE; COLLISION;
D O I
10.1039/ja9900500663
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The collisional line width of the resonance atomic absorption lines of Ca, Cu and In have been measured in graphite furnace atomisers by means of a wavelength modulated echelle spectrometer and a measurement method based on transmission profile fitting. A measurement precision of +/- 0.1 pm is observed for Cu (324.754 nm) based on growth curve shapes measured in peak area or peak height. Time resolved line widths within a single atomisation have been measured for Ca (422.673 nm) and for In (410.176 nm), with a time resolution of 0.3 s and a precision of +/-0.5 pm. This measurement precision is sufficient to show clearly the effect of increased gas pressure on the line width and the line shift. Collisional cross-sections for In and Ca are estimated from the effect of pressure on the line widths and shifts and are compared with previously published values obtained using theoretical calculations.
引用
收藏
页码:663 / 668
页数:6
相关论文
共 58 条
[31]   INTERFEROMETRIC MEASUREMENTS OF SPECTRAL-LINE WIDTHS EMITTED BY AN INDUCTIVELY COUPLED PLASMA [J].
KAWAGUCHI, H ;
OSHIO, Y ;
MIZUIKE, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1982, 37 (09) :809-816
[32]   SPECTRAL-LINE PROFILE MEASUREMENTS FROM CALCIUM, SILVER, AND ALUMINUM HOLLOW-CATHODE LAMPS [J].
KELIHER, PN ;
WOHLERS, CC .
APPLIED SPECTROSCOPY, 1975, 29 (02) :198-200
[33]   APPLICATION OF A PIEZOELECTRIC SCANNING FABRY-PEROT INTERFEROMETER TO STUDY OF ATOMIC LINE SOURCES .3. USE OF CHANNELED SPECTRA PRODUCED WITH A CONTINUUM SOURCE FOR STUDIES OF ABSORPTION LINEWIDTH FOR CALCIUM ATOMS IN FLAMES [J].
KIRKBRIGHT, GF ;
TROCCOLI, OE .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1973, B 28 (02) :33-+
[34]   APPLICATION OF A PIEZOELECTRIC SCANNING FABRY-PEROT INTERFEROMETER TO STUDY OF ATOMIC LINE SOURCES .2. LINE-WIDTHS FOR CALCIUM IN AIR-ACETYLENE AND NITROUS OXIDE-ACETYLENE FLAMES [J].
KIRKBRIGHT, GF ;
TROCCOLI, OE ;
VETTER, S .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1973, B 28 (01) :1-11
[35]   SPECTROPHYSICAL PROPERTIES OF PLASMA OF A HIGH FREQUENCY LOW POWER DISCHARGE IN ARGON AT ATMOSPHERICAL PRESSURE [J].
KLEINMANN, I ;
CAJKO, J .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1970, B 25 (12) :657-+
[36]   INVERSE ZEEMAN SCANNING FOR THE MEASUREMENT OF EMISSION-LINE PROFILE IN FAR ULTRAVIOLET REGION [J].
KOIZUMI, H ;
OISHI, K ;
YASUDA, K .
APPLIED PHYSICS LETTERS, 1982, 40 (02) :122-123
[37]  
KREEGE WC, 1970, J OPT SOC AM, V60, P1100
[38]  
KRIKBRIGHT GF, 1970, SPECTROCHIM ACTA B, V25, P577