PERFUSION QUANTITATION BY ULTRAFAST COMPUTED-TOMOGRAPHY

被引:17
作者
GOULD, RG
机构
关键词
BLOOD FLOW; INDICATOR DILUTION; ULTRAFAST COMPUTED TOMOGRAPHY;
D O I
10.1097/00004424-199212002-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Flow measurements can be made with computed tomography (CT) scanners using iodinated, nonionic contrast media as a first-pass indicator. Ultrafast CT (UFCT) is an ideal machine to make these measurements because of its short scan time (50 mseconds) and interscan delay (less-than-or-equal-to 0.6 seconds). Additionally, UFCT can acquire data at up to eight cross-sectional levels without moving the patient. Direct application of indicator dilution principles permit measurement of cardiac output and has been validated in both animals and humans. However, measurement of myocardial perfusion, an initial design goal of the UFCT scanner, has been difficult. Experiments in animals have consistently underestimated now at high flow rates. Methods to improve accuracy include better accounting for tissue blood volume and minimizing image artifacts.
引用
收藏
页码:S18 / S21
页数:4
相关论文
共 14 条
  • [2] BELL M, 1992, ULTRAFAST COMPUTED T, P215
  • [3] MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW USING ULTRAFAST COMPUTED-TOMOGRAPHY - THEORETICAL ASPECTS
    GOBBEL, GT
    CANN, CE
    FIKE, JR
    [J]. STROKE, 1991, 22 (06) : 768 - 771
  • [4] MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW IN THE DOG USING ULTRAFAST COMPUTED-TOMOGRAPHY - EXPERIMENTAL VALIDATION
    GOBBEL, GT
    CANN, CE
    IWAMOTO, HS
    FIKE, JR
    [J]. STROKE, 1991, 22 (06) : 772 - 779
  • [5] MEASUREMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW IN DOGS BY ULTRAFAST CT
    GOULD, RG
    LIPTON, MJ
    MCNAMARA, MT
    SIEVERS, RE
    KOSHOLD, S
    HIGGINS, CB
    [J]. INVESTIGATIVE RADIOLOGY, 1988, 23 (05) : 348 - 353
  • [6] VALIDATION OF A CT METHOD FOR FLOW DETERMINATION - WORK IN PROGRESS
    GUTHANER, DF
    NASSI, M
    BRADLEY, B
    [J]. RADIOLOGY, 1984, 151 (02) : 429 - 432
  • [7] FLOW MEASUREMENTS WITH A HIGH-SPEED COMPUTED-TOMOGRAPHY SCANNER
    JASCHKE, W
    GOULD, RG
    ASSIMAKOPOULOS, PA
    LIPTON, MJ
    [J]. MEDICAL PHYSICS, 1987, 14 (02) : 238 - 243
  • [8] CINE-CT MEASUREMENT OF CORTICAL RENAL BLOOD-FLOW
    JASCHKE, WR
    GOULD, RG
    COGAN, MG
    SIEVERS, R
    LIPTON, MJ
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) : 779 - 784
  • [9] MULLANI NA, 1983, J NUCL MED, V24, P577
  • [10] USE OF ULTRAFAST COMPUTED-TOMOGRAPHY TO QUANTITATE REGIONAL MYOCARDIAL PERFUSION - A PRELIMINARY-REPORT
    RUMBERGER, JA
    FEIRING, AJ
    LIPTON, MJ
    HIGGINS, CB
    ELL, SR
    MARCUS, ML
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (01) : 59 - 69