HEPATIC CT ENHANCEMENT - A METHOD TO DEMONSTRATE REPRODUCIBILITY

被引:43
作者
CHAMBERS, TP
BARON, RL
LUSH, RM
DODD, GD
MILLER, WJ
CONFER, SR
机构
[1] UNIV PITTSBURGH,MED CTR,DEPT RADIOL,PITTSBURGH,PA 15260
[2] UNIV PITTSBURGH,MED CTR,DEPT PHARMACOL,PITTSBURGH,PA 15260
关键词
COMPUTED TOMOGRAPHY (CT); CONTRAST MEDIA; EFFECTS; LIVER;
D O I
10.1148/radiology.188.3.8351324
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Optimal techniques for intravenous administration of contrast material in computed tomographic (CT) examination of the liver remain controversial mainly because of inaccurate methods of data evaluation. This study tested the reproducibility of hepatic contrast material enhancement within the same patient and the accuracy of two methods of data analysis. Fourteen patients received identical CT examinations. Attenuation of liver and vessels was measured before and after administration of contrast material, and enhancement was calculated for each image. Data were analyzed by averaging enhancement values obtained over 5- and 10-second intervals and by using a new computer program that creates an enhancement-time curve and measures area under the curve (AUC) for any specific time interval. Data were compared between patients' first and second examinations. Mean liver enhancement was nearly identical at all time intervals with the AUC technique. Analysis of interpatient data showed marked variability of all parameters at all measured time intervals, suggesting that results from comparative studies within the same patient may be more accurate than those for studies of two different treatment groups. The AUC technique is preferable to other methods of data analysis for contrast enhancement evaluation.
引用
收藏
页码:627 / 631
页数:5
相关论文
共 10 条
[1]   COMPARISON OF CONTRAST-MEDIA INJECTION RATES AND VOLUMES FOR HEPATIC DYNAMIC INCREMENTED COMPUTED-TOMOGRAPHY [J].
BERLAND, LL ;
LEE, JY .
INVESTIGATIVE RADIOLOGY, 1988, 23 (12) :918-922
[2]   ADDITIONAL COMMENT - DYNAMIC HEPATIC CT [J].
BERLAND, LL .
RADIOLOGY, 1991, 181 (01) :22-23
[3]   RIGHT WINDOW FOR DYNAMIC HEPATIC CT [J].
COX, IH ;
FOLEY, WD ;
HOFFMANN, RG .
RADIOLOGY, 1991, 181 (01) :18-21
[4]   DYNAMIC HEPATIC CT [J].
FOLEY, WD .
RADIOLOGY, 1989, 170 (03) :617-622
[5]   DYNAMIC CONTRAST ENHANCEMENT OF THE UPPER ABDOMEN - EFFECT OF CONTRAST-MEDIUM AND BODY-WEIGHT [J].
KORMANO, M ;
PARTANEN, K ;
SOIMAKALLIO, S ;
KIVIMAKI, T .
INVESTIGATIVE RADIOLOGY, 1983, 18 (04) :364-367
[6]   CT-NUMBER VARIABILITY IN THORACIC GEOMETRY [J].
MCCULLOUGH, EC ;
MORIN, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 141 (01) :135-140
[7]   CONTRAST-ENHANCED CT OF THE LIVER AND SPLEEN - COMPARISON OF IONIC AND NONIONIC CONTRAST AGENTS [J].
NELSON, RC ;
CHEZMAR, JL ;
PETERSON, JE ;
BERNARDINO, ME .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (05) :973-976
[8]   HEPATIC DYNAMIC SEQUENTIAL CT - SECTION ENHANCEMENT PROFILES WITH A BOLUS OF IONIC AND NONIONIC CONTRAST AGENTS [J].
NELSON, RC ;
MOYERS, JH ;
CHEZMAR, JL ;
HOEL, MJ ;
JONES, EC ;
PETERSON, JE ;
CORK, RD ;
BERNARDINO, ME .
RADIOLOGY, 1991, 178 (02) :499-502
[9]   IV CONTRAST MATERIAL FOR ABDOMINAL CT - COMPARISON OF 3 METHODS OF ADMINISTRATION [J].
PLATT, JF ;
GLAZER, GM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (02) :275-277
[10]   DYNAMIC HEPATIC CT - HOW MANY YEARS WILL IT TAKE TIL WE LEARN [J].
WALKEY, MM .
RADIOLOGY, 1991, 181 (01) :17-18