FIBRIN SEALANT REDUCES SUTURE LINE BLEEDING DURING CAROTID ENDARTERECTOMY - A RANDOMIZED TRIAL

被引:53
作者
MILNE, AA
MURPHY, WG
READING, SJ
RUCKLEY, CV
机构
[1] Vascular Surgery Unit, Department of Surgery, University of Edinburgh, Edinburgh
[2] Department of Medicine, University of Edinburgh, Edinburgh
[3] Product Services Dept, Scottish National Blood Transfusion Service, Scotland
关键词
RANDOMIZED CONTROLLED TRIAL; POLYTETRAFLUOROETHYLENE; CAROTID SURGERY; FIBRIN SEALANT; HEMOSTASIS;
D O I
10.1016/S1078-5884(05)80203-5
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: To determine whether topical fibrin sealant reduced suture line bleeding during carotid endarterectomy with polytetrafluoroethylene (PTFE) patch closure. Design: Prospective randomised non-blinded control trial. Setting Regional vascular surgery unit. Materials: Seventeen patients undergoing carotid endarterectomy were ramdomised either to receive fibrin sealant as a topical haemostatic agent at the arteriotomy suture line or to act as control. Outcome measures: Time taken to achieve haemostasis at the suture line. Intraoperative blood loss. Total operative time. Results: The median time to achieve haemostasis was 5.5 min (range 4-31 min) in the treatment group and 19 min (range 10-47 min) in the control group. This difference was statistically significant p < 0.005 by Mann-Whitney test. There was no statistical difference in total operative rime. Operative blood loss was lower in the treatment group (median 420ml, range 300-500ml) than in the control group (median 550ml, range 350-1200ml) but this difference was not statistically significant. One patient in the control group suffered a perioperative thrombo-embolic event. Conclusion: Fibrin sealant is an effective topical haemost atic agent for arteriotomy suture lines involving PTFE material.
引用
收藏
页码:91 / 94
页数:4
相关论文
共 36 条
  • [31] Byrne, Hardy, Wood, McIntosh, Cischieri, Effect of fibrin glues on the mechanical properties of healing wounds, Br J Surg, 78, pp. 841-843, (1991)
  • [32] Harris, Siedentop, Ham, Sanchez, Autologous fibrin tissue adhesive biodegradation and systemic effects, Laryngoscope, 97, pp. 1141-1144, (1987)
  • [33] Jonas, Schoen, Ziemer, Britton, Castaneda, Biological sealants and knitted dacron conduits: Comparison of collagen and fibrin glue pretreatments in circulatory models, Ann Thorac Surg, 44, pp. 283-290, (1987)
  • [34] Jonas, Schoen, Levy, Castaneda, Biological sealants and knitted dacron: porosity and histological comparisons of vascular graft materials with and without collagen and fibrin glue pretreatments, Ann Thorac Surg, 41, pp. 657-663, (1986)
  • [35] Wilson, Pell, Donegan, HIV-1 transmission following the use of cryoprecipitated fibrinogen as a gel/adhesive, Transfusion, 31, (1991)
  • [36] Bove, Fibrinogen — Is it worth the risk?, Transfusion, 19, pp. 129-136, (1978)