ION-SELECTIVE MICROCHEMICAL SENSORS WITH REDUCED PRECONDITIONING TIME - MEMBRANE BIOSTABILITY STUDIES AND APPLICATIONS IN BLOOD ANALYSIS

被引:38
作者
COSOFRET, VV
ERDOSY, M
LINDNER, E
JOHNSON, TA
BUCK, RP
KAO, WJ
NEUMAN, MR
ANDERSON, JM
机构
[1] UNIV N CAROLINA,DEPT MED,CHAPEL HILL,NC 27599
[2] CASE WESTERN RESERVE UNIV,DEPT BIOMED ENGN,CLEVELAND,OH 44106
关键词
PLANAR MICROCHEMICAL SENSORS; POLYMERIC MEMBRANES; BLOOD ANALYSIS; MEMBRANE BIOSTABILITY;
D O I
10.1080/00032719408000310
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Progress on solution of two general problems regarding the use of in vivo planar microchemical sensors is reported. These are issues of short term and long term response stability. Reduction of preconditioning time (hydration period), i.e., the time needed by the planar microchemical sensors based on Kapton(R) substrate to achieve the optimal analytical performances, has been achieved. By storing the electrodes in containers with humid atmospheres (100% humidity) their short time responses, e.g. measured potential, when placed in samples to be analyzed, are practically constant after one minute of immersion. The electrode sensitivity, potential reproducibility and membrane resistance of both pH and K+ sensors were evaluated and compared before and after placing them in whole blood samples for specified periods of time. Blood serum samples were successfully assayed and the results compared with those obtained with a pH glass electrode and a blood gas analyzer, respectively. The long term stability of the membranes for in vivo use was investigated by determination of cell adhesion and membrane biostability (at 14 days of subcutaneous implantation in rats) using scanning electron microscopy.
引用
收藏
页码:3039 / 3063
页数:25
相关论文
共 32 条
  • [1] LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS
    AMMANN, D
    PRETSCH, E
    SIMON, W
    LINDNER, E
    BEZEGH, A
    PUNGOR, E
    [J]. ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) : 119 - 129
  • [2] RECOMMENDED PROCEDURES FOR CALIBRATION OF ION-SELECTIVE ELECTRODES
    BUCK, RP
    COSOFRET, VV
    [J]. PURE AND APPLIED CHEMISTRY, 1993, 65 (08) : 1849 - 1858
  • [3] BUCK RP, 1993, ANAL CHIM ACTA, V282, P373
  • [4] NEW NEUTRAL CARRIER-BASED H+ SELECTIVE-MEMBRANE ELECTRODES
    COSOFRET, VV
    NAHIR, TM
    LINDNER, E
    BUCK, RP
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 327 (1-2): : 137 - 146
  • [5] PLANAR MICRO SENSORS FOR IN-VIVO MYOCARDIAL PH MEASUREMENTS
    COSOFRET, VV
    LINDNER, E
    JOHNSON, TA
    NEUMAN, MR
    [J]. TALANTA, 1994, 41 (06) : 931 - 938
  • [6] ELECTROCHEMICAL CHARACTERIZATION OF AMINATED PVC-BASED ION-SELECTIVE MEMBRANES
    COSOFRET, VV
    LINDNER, E
    BUCK, RP
    KUSY, RP
    WHITLEY, JQ
    [J]. ELECTROANALYSIS, 1993, 5 (9-10) : 725 - 730
  • [7] COSOFRET VV, 1993, P AM CHEM SOC, V70, P137
  • [8] COSOFRET VV, UNPUB ANAL CHEM JUN
  • [9] COSOFRET VV, 1994, IN PRESS ANALYST
  • [10] PVC MATRIX MEMBRANE ION-SELECTIVE ELECTRODES - CONSTRUCTION AND LABORATORY EXPERIMENTS
    CRAGGS, A
    MOODY, GJ
    THOMAS, JDR
    [J]. JOURNAL OF CHEMICAL EDUCATION, 1974, 51 (08) : 541 - 544