REAL-TIME ANALYSIS OF BREATH USING AN ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETER

被引:66
作者
LOVETT, AM [1 ]
REID, NM [1 ]
BUCKLEY, JA [1 ]
FRENCH, JB [1 ]
CAMERON, DM [1 ]
机构
[1] UNIV TORONTO,INST AEROSP STUDIES,DOWNSVIEW M3H 5T6,ONTARIO,CANADA
来源
BIOMEDICAL MASS SPECTROMETRY | 1979年 / 6卷 / 03期
关键词
D O I
10.1002/bms.1200060302
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new technique is reported resulting in the direct, instantaneous analyses of trace compounds in breath. The analyses were performed using a commercial atmospheric pressure chemical ionization mass spectrometer (TAGA TM 2000 APCI mass spectrometer). A known flow of breath sample is introduced into the ionization region of the mass spectrometer. The study includes the measurement and monitoring in real‐time, of breath ammonia during a 24 hour and a 48 hour period. The ammonia profiles indicate a personalized daily pattern associated with each subject. This method appears to be of potential value in routine detection and treatment of hyperammonemia patients. Results also show that it is possible to obtain instantaneous analyses of several naturally occurring metabolites and other substances on breath in the ppm to ppt range, suggesting a number of diagnostic research applications. Copyright © 1979 Heyden & Son Ltd
引用
收藏
页码:91 / 97
页数:7
相关论文
共 24 条
[1]  
BUCKLEY JA, 1974, CAN AERONAUT SPACE J, V20, P231
[2]  
BUCKLEY JA, 1974, THESIS U TORONTO
[3]  
CADE JR, 1972, 1971 P INT C PHYS SO
[4]  
CAMERON DM, 1976, THESIS U TORONTO
[5]   TRACE COMPOSITION OF HUMAN RESPIRATORY GAS [J].
CONKLE, JP ;
CAMP, BJ ;
WELCH, BE .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1975, 30 (06) :290-295
[6]   COMPARISON OF POSITIVE-IONS FORMED IN NICKEL-63 AND CORONA DISCHARGE ION SOURCES USING NITROGEN, ARGON, ISOBUTANE, AMMONIA AND NITRIC-OXIDE AS REAGENTS IN ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY [J].
DZIDIC, I ;
CARROLL, DI ;
STILLWELL, RN ;
HORNING, EC .
ANALYTICAL CHEMISTRY, 1976, 48 (12) :1763-1768
[7]   ATMOSPHERIC-PRESSURE IONIZATION (API) MASS-SPECTROMETRY - FORMATION OF PHENOXIDE IONS FROM CHLORINATED AROMATIC-COMPOUNDS [J].
DZIDIC, I ;
CARROLL, DI ;
STILLWELL, RN ;
HORNING, EC .
ANALYTICAL CHEMISTRY, 1975, 47 (08) :1308-1312
[8]  
ERIKSEN S, 1964, NEW SCI, V381, P608
[9]  
FRENCH JB, 1977, 25TH ANN C MASS SPEC, P122
[10]   ION-MOLECULE REACTIONS IN PURE NITROGEN AND NITROGEN CONTAINING TRACES OF WATER AT TOTAL PRESSURES 0.5-4 TORR KINETICS OF CLUSTERING REACTIONS FORMING H+(H2O)N [J].
GOOD, A ;
DURDEN, DA ;
KEBARLE, P .
JOURNAL OF CHEMICAL PHYSICS, 1970, 52 (01) :212-&