IMMUNOSENSING WITH PHOTOIMMOBILIZED IMMUNOREAGENTS ON PLANAR OPTICAL-WAVE GUIDES

被引:40
作者
GAO, H [1 ]
SANGER, M [1 ]
LUGINBUHL, R [1 ]
SIGRIST, H [1 ]
机构
[1] UNIV BERN,INST BIOCHEM,CH-3012 BERN,SWITZERLAND
关键词
IMMUNOCHEMICAL SENSOR; ANTIBODY IMMOBILIZATION; PHOTO-IMMOBILIZATION; INTEGRATED OPTICS; TITANIUM OXIDE SILICON OXIDE; ENZYME-LINKED IMMUNOASSAY;
D O I
10.1016/0956-5663(95)96850-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Immunocomplexation at wave guiding TiO2/SiO2 surfaces was investigated using an integrated optical grating coupler. For extended application of this label-free monitoring system, F(ab')(2) fragments of monoclonal antibodies were photo-immobilized by photolinker polymer-mediated procedures that do not require functionalization of either the immunoreagent or the TiO2/SiO2 surface. Covalent, light-dependent binding of photolinker polymer and F(ab')(2) fragments was achieved using a single-step photo-reaction. Bovine serum albumin derivatized with aryldiazirines (T-BSA) served as a photolinker polymer. T-BSA suppressed the non-specific adsorption of analytes to wave guide surfaces. Immunoreagent binding and immunological activity were analyzed and modified surfaces were investigated by scanning force microscopy. Apparent immunoreagent surface densities were 16.7 fmol F(ab')(2) per mm(2) sensor surface. Optical analyses revealed linear, dose-dependent antigen binding with label free analytes. Immunocompetent surfaces were regenerable by treatment at pH 2.3, rendering the immunosensing system applicable for repetitive use.
引用
收藏
页码:317 / 328
页数:12
相关论文
共 24 条
  • [11] LOWRY OH, 1951, J BIOL CHEM, V193, P265
  • [12] SENSITIVITY OF INTEGRATED OPTICAL GRATING AND PRISM COUPLERS AS (BIO)CHEMICAL SENSORS
    LUKOSZ, W
    TIEFENTHALER, K
    [J]. SENSORS AND ACTUATORS, 1988, 15 (03): : 273 - 284
  • [13] ATTEMPTS TO MIMIC DOCKING PROCESSES OF THE IMMUNE-SYSTEM - RECOGNITION-INDUCED FORMATION OF PROTEIN MULTILAYERS
    MULLER, W
    RINGSDORF, H
    RUMP, E
    WILDBURG, G
    ZHANG, X
    ANGERMAIER, L
    KNOLL, W
    LILEY, M
    SPINKE, J
    [J]. SCIENCE, 1993, 262 (5140) : 1706 - 1708
  • [14] INTEGRATED OPTICAL INPUT GRATING COUPLERS AS DIRECT AFFINITY SENSORS
    NELLEN, PM
    LUKOSZ, W
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (3-4) : 129 - 147
  • [15] INTEGRATED OPTICAL INPUT GRATING COUPLERS AS BIOCHEMICAL SENSORS
    NELLEN, PM
    TIEFENTHALER, K
    LUKOSZ, W
    [J]. SENSORS AND ACTUATORS, 1988, 15 (03): : 285 - 295
  • [16] SERUM-ALBUMIN
    PETERS, T
    [J]. ADVANCES IN PROTEIN CHEMISTRY, 1985, 37 : 161 - 245
  • [17] ONLINE MONITORING OF MONOCLONAL-ANTIBODIES IN ANIMAL-CELL CULTURE USING A GRATING COUPLER
    POLZIUS, R
    BIER, FF
    BILITEWSKI, U
    JAGER, V
    SCHMID, RD
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1993, 42 (11) : 1287 - 1292
  • [18] SABY C, 1993, SENSOR ACTUAT B-CHEM, V15, P458
  • [19] SANGER M, 1992, BIOCONJUGATE CHEM, V3, P308
  • [20] THE DIFFERENCE INTERFEROMETER - APPLICATION AS A DIRECT AFFINITY SENSOR
    SCHLATTER, D
    BARNER, R
    FATTINGER, C
    HUBER, W
    HUBSCHER, J
    HURST, J
    KOLLER, H
    MANGOLD, C
    MULLER, F
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (02) : 109 - 116