COMPARISON OF BREATH-HOLD FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES FOR T2-WEIGHTED MR-IMAGING OF LIVER-LESIONS

被引:102
作者
RYDBERG, JN
LOMAS, DJ
COAKLEY, KJ
HOUGH, DM
EHMAN, RL
RIEDERER, SJ
机构
[1] MAYO CLIN & MAYO FDN, DEPT DIAGNOST RADIOL, MAGNET RESONANCE LAB, ROCHESTER, MN 55905 USA
[2] UNIV MINNESOTA, DEPT BIOMED ENGN, MINNEAPOLIS, MN 55455 USA
关键词
LIVER NEOPLASMS; MR; MAGNETIC RESONANCE (MR); COMPARATIVE STUDIES; PULSE SEQUENCES; RAPID IMAGING;
D O I
10.1148/radiology.194.2.7824723
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate a breath-hold fast spin-echo (SE) technique for T2-weighted magnetic resonance (MR) imaging of liver lesions. MATERIALS AND METHODS: A fast SE technique was developed that enabled six sections to be imaged per 16-second breath hold with a single echo. Resulting images were compared with those obtained with the first echo of a conventional dual-echo T2-weighted SE sequence (16 minutes 55 seconds for 18 sections). Thirty-one patients with malignant focal hepatic lesions were studied prospectively. The images were compared quantitatively and qualitatively. RESULTS: Quantitatively, the contrast and contrast-to-noise ratios for the fast SE images were 20% +/- 5 and 19% +/- 8 greater, respectively, than those for the conventional T2-weighted SE images of the 54 representative lesions. Qualitatively, fast SE images had less image artifact, enabled comparable or better lesion sizing, and greatly improved depiction of extrahepatic structures compared with conventional T2-weighted SE images. CONCLUSION: The fast SE technique with breath holding provides diagnostically useful liver images in a greatly decreased acquisition time.
引用
收藏
页码:431 / 437
页数:7
相关论文
共 37 条
[1]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[2]  
BOTTOMLEY PA, 1984, MED PHYS, V11, P425, DOI 10.1118/1.595535
[3]   ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM [J].
BUTTS, K ;
RIEDERER, SJ ;
EHMAN, RL ;
FELMLEE, JP ;
GRIMM, RC .
RADIOLOGY, 1993, 189 (01) :259-264
[4]  
BUTTS RK, IN PRESS MAGN RESON
[5]   T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES [J].
CATASCA, JV ;
MIROWITZ, SA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) :61-67
[6]   FACTORS INFLUENCING CONTRAST IN FAST SPIN-ECHO MR IMAGING [J].
CONSTABLE, RT ;
ANDERSON, AW ;
ZHONG, J ;
GORE, JC .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :497-511
[7]   GRASE (GRADIENT-ECHO AND SPIN-ECHO) MR IMAGING - A NEW FAST CLINICAL IMAGING TECHNIQUE [J].
FEINBERG, DA ;
OSHIO, K .
RADIOLOGY, 1991, 181 (02) :597-602
[8]  
Glover G, 1991, BOOK ABSTR SOC MAGNE, P1242
[9]  
GOLDBERG M, 1992, AJR, V160, P1011
[10]   RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR [J].
HENNIG, J ;
NAUERTH, A ;
FRIEDBURG, H .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :823-833