摘要
Real-world environmental samples which contain high concentrations of water and/or extractable matrix components frequently cause intermittent or irreversible plugging of capillary flow restrictors during off-line supercritical fluid extraction. Heating the entire restrictor at 50-degrees-C produces a constant extraction flow-rate (+/-0.03 ml/min) for such samples, but poor collection efficiencies (30-65% recovery for polycyclic aromatic hydrocarbons) were obtained because the supercritical fluid could not be depressurized directly into the collection solvent. While the collection efficiency was improved (80-90%) by nebulizing an organic solvent with the restrictor effluent, a simpler method was to heat all but the last 3 cm of the restrictor and to depressurize the extract directly in the collection solvent. Depending on the sample matrix, restrictor heater temperatures ranging from 50 to 200-degrees-C were required to avoid restrictor plugging. With proper heating, constant extraction flow-rates (+/-0.07 ml/min) and high collection efficiencies (90-100%) for polycyclic aromatic hydrocarbons and n-alkanes as volatile as n-octane were achieved.
引用
收藏
页码:321 / 332
页数:12
相关论文
共 22 条
  • [11] PERFORMANCE OF CAPILLARY RESTRICTORS IN SUPERCRITICAL FLUID CHROMATOGRAPHY
    SMITH, RD
    FULTON, JL
    PETERSEN, RC
    KOPRIVA, AJ
    WRIGHT, BW
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (09) : 2057 - 2064
  • [12] QUICK METHOD FOR MICROANALYTICAL EVALUATION OF DISSOLVING POWER OF SUPERCRITICAL GASES
    STAHL, E
    SCHILZ, W
    SCHUTZ, E
    WILLING, E
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1978, 17 (10): : 731 - 738
  • [13] NEW DEVELOPMENTS IN THE FIELD OF HIGH-PRESSURE EXTRACTION OF NATURAL-PRODUCTS WITH DENSE GASES
    STAHL, E
    QUIRIN, KW
    GLATZ, A
    GERARD, D
    RAU, G
    [J]. BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1984, 88 (09): : 900 - 907
  • [14] SUPERCRITICAL FLUID EXTRACTION FROM A BROWN ALGA BY STAGEWISE PRESSURE INCREASE
    SUBRA, P
    BOISSINOT, P
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 543 (02): : 413 - 424
  • [15] SuYnchez-Camargo A.P., 2014, REV CHEM ENG, V1, P1, DOI [10.1016/B978-0-12-409547-2.10753-X, DOI 10.1016/B978-0-12-409547-2.10753-X]
  • [16] TAKEUCHI M, 1991, HRC-J HIGH RES CHROM, V14, P347
  • [17] POST-EXTRACTION SOLVENT FLUSH OF THE PRESSURE RESTRICTOR IN SUPERCRITICAL FLUID EXTRACTION
    THOMSON, CA
    CHESNEY, DJ
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 543 (01): : 187 - 194
  • [18] WISSER J, COMMUNICATION
  • [19] DETERMINATION OF VOLATILE AND SEMIVOLATILE MUTAGENS IN AIR USING SOLID ADSORBENTS AND SUPERCRITICAL FLUID EXTRACTION
    WONG, JM
    KADO, NY
    KUZMICKY, PA
    NING, HS
    WOODROW, JE
    HSIEH, DPH
    SEIBER, JN
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (15) : 1644 - 1650
  • [20] ANALYTICAL SUPERCRITICAL FLUID EXTRACTION OF ADSORBENT MATERIALS
    WRIGHT, BW
    WRIGHT, CW
    GALE, RW
    SMITH, RD
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (01) : 38 - 44