HEPATIC HELICAL CT - CONTRAST MATERIAL INJECTION PROTOCOL

被引:94
作者
FOLEY, WD
HOFFMANN, RG
QUIROZ, FA
KAHN, CE
PERRET, RS
机构
[1] Department of Radiology, Medical College of Wisconsin, Doyne Hospital/Doyne Clinic-151, Milwaukee, WI 53226
关键词
AORTA; CT; COMPUTED TOMOGRAPHY (CT); CONTRAST MEDIA; HELICAL TECHNOLOGY; LIVER;
D O I
10.1148/radiology.192.2.8029399
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To develop and compare contrast material injection protocols suitable for hepatic helical computed tomography (CT). MATERIALS AND METHODS: Monophasic and biphasic helical CT were performed with contrast material with an iodine load of 50 g at 3 mL/sec for 60 seconds or at 5 mL/sec for 10 seconds and 2 mL/sec for 65 seconds, respectively. In 58 men and 51 women, aged 22-77 years, aortic and hepatic enhancement curves were constructed from a cluster acquisition with a slip-ring scanner operating in a nonhelical mode. RESULTS: The monophasic protocol produced a higher peak aortic enhancement (180 HU +/- 47 [+/-1 standard deviation]) than the biphasic protocol (150 HU + 24). Peak hepatic enhancement (63-64 HU +/- 15) was equivalent. Calculated equilibrium time for the monophasic protocol was 95.1 seconds and for the biphasic protocol was 101.4 seconds. The contrast enhancement index differed only marginally between the two protocols (P <.4). CONCLUSION: Monophasic and biphasic protocols produced equivalent results when tailored for the shorter temporal window of a rapid-sequence helical acquisition.
引用
收藏
页码:367 / 371
页数:5
相关论文
共 16 条
  • [1] [Anonymous], APPL REGRESSION ANAL
  • [2] BATES DM, 1988, NONLINEAR REGRESSION, P168
  • [3] COMPARISON OF CONTRAST-MEDIA INJECTION RATES AND VOLUMES FOR HEPATIC DYNAMIC INCREMENTED COMPUTED-TOMOGRAPHY
    BERLAND, LL
    LEE, JY
    [J]. INVESTIGATIVE RADIOLOGY, 1988, 23 (12) : 918 - 922
  • [4] SPIRAL CT ARTERIAL PORTOGRAPHY OF THE LIVER
    BLUEMKE, DA
    FISHMAN, EK
    [J]. RADIOLOGY, 1993, 186 (02) : 576 - 579
  • [5] SPIRAL CT OF THE LIVER
    BLUEMKE, DA
    FISHMAN, EK
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (04) : 787 - 792
  • [6] HEPATIC CT ENHANCEMENT - A METHOD TO DEMONSTRATE REPRODUCIBILITY
    CHAMBERS, TP
    BARON, RL
    LUSH, RM
    DODD, GD
    MILLER, WJ
    CONFER, SR
    [J]. RADIOLOGY, 1993, 188 (03) : 627 - 631
  • [7] RIGHT WINDOW FOR DYNAMIC HEPATIC CT
    COX, IH
    FOLEY, WD
    HOFFMANN, RG
    [J]. RADIOLOGY, 1991, 181 (01) : 18 - 21
  • [8] SPIRAL CT OF THE PANCREAS
    DUPUY, DE
    COSTELLO, P
    ECKER, CP
    [J]. RADIOLOGY, 1992, 183 (03) : 815 - 818
  • [9] FISHMAN EK, 1992, AJR AM J ROENTGENOL, V159, P209
  • [10] DYNAMIC HEPATIC CT
    FOLEY, WD
    [J]. RADIOLOGY, 1989, 170 (03) : 617 - 622