RELIABILITY OF CEREBRAL MEASURES IN REPEATED EXAMINATIONS WITH MAGNETIC-RESONANCE-IMAGING

被引:24
作者
GIEDD, JN [1 ]
KOZUCH, P [1 ]
KAYSEN, D [1 ]
VAITUZIS, AC [1 ]
HAMBURGER, SD [1 ]
BARTKO, JJ [1 ]
RAPOPORT, JL [1 ]
机构
[1] NIMH,DIV EPIDEMIOL & SERV RES,BETHESDA,MD 20892
关键词
BRAIN; MORPHOLOGY; MRI RESCAN RELIABILITY; CAUDATE NUCLEUS; CEREBRUM; CORPUS CALLOSUM;
D O I
10.1016/0925-4927(95)02593-M
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This study examined the reliability of quantitative measures of cerebral magnetic resonance images (MRI) in repeated scans. Ten subjects were scanned twice, at 2- to 4-week intervals. Volumetric data from 14 regions of the cerebrum, the caudate nucleus, and the lateral ventricles and area measures of the corpus callosum were acquired. Intrarater and scan-rescan reliabilities, including the relative percent error from each of these two sources, were determined for each structure, Intraclass correlations ranged from 0.88 for the head of the caudate nucleus to 0.99 for the ventricular volume, Quantitative cerebral MRI measures of these structures are stable over time intervals of 2-4 weeks.
引用
收藏
页码:113 / 119
页数:7
相关论文
共 8 条
[1]   METHODS AND THEORY OF RELIABILITY [J].
BARTKO, JJ ;
CARPENTER, WT .
JOURNAL OF NERVOUS AND MENTAL DISEASE, 1976, 163 (05) :307-317
[2]   RELIABILITY OF IN-VIVO VOLUME MEASURES OF HIPPOCAMPUS AND OTHER BRAIN STRUCTURES USING MRI [J].
BARTZOKIS, G ;
MINTZ, J ;
MARX, P ;
OSBORN, D ;
GUTKIND, D ;
CHIANG, F ;
PHELAN, CK ;
MARDER, SR .
MAGNETIC RESONANCE IMAGING, 1993, 11 (07) :993-1006
[3]   THE CONSORTIUM TO ESTABLISH A REGISTRY FOR ALZHEIMERS-DISEASE (CERAD) .3. RELIABILITY OF A STANDARDIZED MRI EVALUATION OF ALZHEIMERS-DISEASE [J].
DAVIS, PC ;
GRAY, L ;
ALBERT, M ;
WILKINSON, W ;
HUGHES, J ;
HEYMAN, A ;
GADO, M ;
KUMAR, AJ ;
DESTIAN, S ;
LEE, C ;
DUVALL, E ;
KIDO, D ;
NELSON, MJ ;
BELLO, J ;
WEATHERS, S ;
JOLESZ, F ;
KIKINIS, R ;
BROOKS, M .
NEUROLOGY, 1992, 42 (09) :1676-1680
[4]   TISSUE CHARACTERIZATION BY MAGNETIC-RESONANCE SPECTROSCOPY AND IMAGING - RESULTS OF A CONCERTED RESEARCH-PROJECT OF THE EUROPEAN-ECONOMIC-COMMUNITY .4. IN-VIVO MEASUREMENTS OF PROTON RELAXATION-TIMES IN HUMAN BRAIN, LIVER, AND SKELETAL-MUSCLE - A MULTICENTER MRI STUDY [J].
DECERTAINES, JD ;
HENRIKSEN, O ;
SPISNI, A ;
CORTSEN, M ;
RING, PB .
MAGNETIC RESONANCE IMAGING, 1993, 11 (06) :841-850
[5]   SOURCES OF ERROR IN THE QUANTITATIVE-ANALYSIS OF MRI SCANS [J].
PLANTE, E ;
TURKSTRA, L .
MAGNETIC RESONANCE IMAGING, 1991, 9 (04) :589-595
[6]  
RASBAND W, 1993, IMAGE 1 6
[7]  
Williams P.L., 1989, GRAYS ANATOMY
[8]  
WOODS BT, 1991, PSYCHIAT RES-NEUROIM, V40, P1