IONTOPHORETIC TRANSPORT THROUGH POROUS MEMBRANES USING SCANNING ELECTROCHEMICAL MICROSCOPY - APPLICATION TO INVITRO STUDIES OF ION FLUXES THROUGH SKIN

被引:139
作者
SCOTT, ER
WHITE, HS
PHIPPS, JB
机构
[1] UNIV MINNESOTA, DEPT CHEM ENGN & MAT SCI, MINNEAPOLIS, MN 55455 USA
[2] ALZA CORP, SPRING LAKE PK, MN 55432 USA
关键词
D O I
10.1021/ac00059a010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Scanning electrochemical microscopy (SECM) is used to map localized iontophoretic fluxes of electroactive species through porous membranes. A method is described that allows both the rate of transport of species from a microscopic pore and the pore's diameter to be measured. SECM images and analyses of synthetic porous membranes (track-etched polycarbonate and mica membranes) and hairless mouse skin are reported. Preliminary analysis of SECM images of the mouse skin indicates that a significant percentage of the iontophoretic flux occurs through pores associated with hair follicles.
引用
收藏
页码:1537 / 1545
页数:9
相关论文
共 22 条
[1]  
Adams R. N., 1969, ELECTROCHEMISTRY SOL
[2]   SCANNING ELECTROCHEMICAL MICROSCOPY - A NEW TECHNIQUE FOR THE CHARACTERIZATION AND MODIFICATION OF SURFACES [J].
BARD, AJ ;
DENUAULT, G ;
LEE, C ;
MANDLER, D ;
WIPF, DO .
ACCOUNTS OF CHEMICAL RESEARCH, 1990, 23 (11) :357-363
[3]   CHEMICAL IMAGING OF SURFACES WITH THE SCANNING ELECTROCHEMICAL MICROSCOPE [J].
BARD, AJ ;
FAN, FRF ;
PIERCE, DT ;
UNWIN, PR ;
WIPF, DO ;
ZHOU, FM .
SCIENCE, 1991, 254 (5028) :68-74
[4]   METHODS FOR INVITRO PERCUTANEOUS-ABSORPTION STUDIES .2. ANIMAL-MODELS FOR HUMAN-SKIN [J].
BRONAUGH, RL ;
STEWART, RF ;
CONGDON, ER .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 1982, 62 (03) :481-488
[5]   CHARACTERIZATION OF THE PORE TRANSPORT-PROPERTIES AND TISSUE ALTERATION OF EXCISED HUMAN-SKIN DURING IONTOPHORESIS [J].
BURNETTE, RR ;
ONGPIPATTANAKUL, B .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1988, 77 (02) :132-137
[6]   SITES OF IONTOPHORETIC CURRENT FLOW INTO THE SKIN - IDENTIFICATION AND CHARACTERIZATION WITH THE VIBRATING PROBE ELECTRODE [J].
CULLANDER, C ;
GUY, RH .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1991, 97 (01) :55-64
[7]  
GRIMNES S, 1984, ACTA DERM-VENEREOL, V64, P93
[8]  
GUY RH, 1992, ADV DRUG REV, V9
[9]   SCANNING ELECTROCHEMICAL MICROSCOPY - THEORY OF THE FEEDBACK MODE [J].
KWAK, J ;
BARD, AJ .
ANALYTICAL CHEMISTRY, 1989, 61 (11) :1221-1227
[10]   SCANNING ELECTROCHEMICAL MICROSCOPY - APPARATUS AND TWO-DIMENSIONAL SCANS OF CONDUCTIVE AND INSULATING SUBSTRATES [J].
KWAK, J ;
BARD, AJ .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1794-1799