DIURNAL BLOOD-PRESSURE VARIABILITY AND PHYSICAL-ACTIVITY MEASURED ELECTRONICALLY AND BY DIARY

被引:65
作者
GRETLER, DD [1 ]
CARLSON, GF [1 ]
MONTANO, AV [1 ]
MURPHY, MB [1 ]
机构
[1] UNIV CHICAGO,COMM CLIN PHARMACOL,CHICAGO,IL 60637
关键词
AMBULATORY BLOOD PRESSURE MONITORING; PHYSICAL ACTIVITY; BLOOD PRESSURE;
D O I
10.1093/ajh/6.2.127
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
In order for 24 h ambulatory blood pressure monitoring (ABPM) to be useful in clinical decision making, it is necessary to quantify ambient physical activity and to develop appropriate norms of ambulatory pressure for different levels of activity. The present study has compared the predictive value of physical activity determined by an electronic activity monitor or a written diary, for concomitantly recorded blood pressure during ABPM in healthy normotensive subjects. Each subject wore four activity monitors, on the right and left wrists, on the left ankle and at the waist, respectively. Linear regression analysis was performed for each subject to determine-the correlation between ABPM data (systolic and diastolic blood pressure and heart rate) and activity data (obtained from diaries and the four monitors). Significant differences in the degree of correlation were found for both the location of the activity monitor and the time (1/2, 2, 5, 10, 15, and 30 min preceding blood pressure measurement) over which activity was averaged (P < .05 by two-way analysis of variance). The best correlation was obtained with the activity monitor worn on the dominant wrist, and when activity was averaged over 2 to 10 min preceding blood pressure determination, accounting for 18 to 69% (mean 36 +/- 5%) of systolic blood pressure variation. Diaries performed similarly in these well-motivated subjects. It is concluded that because of the significant interaction between activity and blood pressure, ABPM data should be interpreted only in the light of concomitant activity data. The electronic activity monitor is an easy to use, reliable means of recording physical activity for this purpose, requiring no subject participation and performing at least as well as traditional diaries.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 39 条
  • [21] James G.D., Yee L.S., Harshfield G.A., Et al., The influence of happiness, anger and anxiety on the blood pressure of borderline hypertensives, Psychosom Med, 48, pp. 502-508, (1986)
  • [22] James G.D., Pickering T.G., Ambulatory blood pressure monitoring: Assessing the diurnal variation in blood pressure, Am J Phys Anthropol, 84, pp. 343-349, (1991)
  • [23] Van Egeren L.F., Madarasmi S., A computer-assisted diary (CAD) for ambulatory blood pressure monitoring, Am J Hypertens, 1, pp. 179S-185S, (1988)
  • [24] Roffe D.J., Bertram C.D., Hunyor S.N., Real time detection of significant blood pressure events in ambulant subjects, Clin Exp Hypertens [A], A7, pp. 299-307, (1985)
  • [25] Webster J.B., Messin S., Mullaney D.J., Kripke D.F., Transducer design and placement for activity recording, Med Biol Eng Comput, 20, pp. 741-744, (1982)
  • [26] Benoit O., Royant-Parola S., Borbely A.A., Et al., Circadian aspects of motor activity in depressed patients, Acta Psy- Chiatr Belg, 85, pp. 582-592, (1985)
  • [27] Van Egeren L.F., Computer-based monitoring of physical activity, Medical Monitoring in the Home and Work Environment, pp. 151-163, (1989)
  • [28] Frohlich E.D., Grim C., Labarthe D.R., Et al., Recommendations for human blood pressure determination by sphygmomanometers, Hypertension, 11, pp. 210A-222A, (1988)
  • [29] Fumo M.T., Teeger S., Lang R.M., Et al., Diurnal blood pressure variation and cardiac mass in American blacks and whites, and South African blacks, Am J Hypertens, 5, pp. 111-116, (1992)
  • [30] Jauhar R., Fumo M.T., Gretler D.D., Murphy M.B., Normal ambulatory BP values must incorporate effects of variable daily activity levels (Abst), Am J Hypertens, 99 A, (1991)