THE OPTIMAL COOLING OF A STACK OF HEAT GENERATING BOARDS WITH FIXED PRESSURE-DROP, FLOW-RATE OR PUMPING POWER

被引:45
作者
MEREU, S [1 ]
SCIUBBA, E [1 ]
BEJAN, A [1 ]
机构
[1] DUKE UNIV, DEPT MECH ENGN & MAT SCI, DURHAM, NC 27706 USA
关键词
D O I
10.1016/0017-9310(93)90047-A
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, we show analytically how to optimize the spacing between heat generating boards in a stack cooled by single-phase laminar forced convection. The thickness of each board is not negligible. The theoretical results for optimal spacing and maximum overall thermal conductance between stack and coolant are validated by means of numerical simulations of the complete flow and temperature fields. Results are reported for three different situations, which are dictated by the way in which the stack is attached to the rest of the cooling network of the electronics package: (1) fixed pressure drop, (2) fixed mass flowrate, and (3) fixed pumping power.
引用
收藏
页码:3677 / 3686
页数:10
相关论文
共 16 条
[11]  
Knight R.W., 1991, ASME J ELECT PACKAG, V113, P313, DOI [10.1115/1.2905412, DOI 10.1115/1.2905412]
[12]  
LEVY EK, 1971, HEAT TRANSFER, V93, P463
[13]  
PETERSON GP, 1990, ADV HEAT TRANSFER, V20, P18
[14]  
SCHMIDT RC, 1986, ASME86WAHT88 PAP
[15]   HIGH-PERFORMANCE HEAT SINKING FOR VLSI [J].
TUCKERMAN, DB ;
PEASE, RFW .
ELECTRON DEVICE LETTERS, 1981, 2 (05) :126-129
[16]  
1991, FIDAP THEORETICAL MA