TAG CONTRAST IN BREATH-HOLD CINE CARDIAC MRI

被引:24
作者
REEDER, SB
MCVEIGH, ER
机构
[1] JOHNS HOPKINS UNIV,SCH MED,DEPT BIOMED ENGN,MED IMAGING LAB,BALTIMORE,MD 21205
[2] JOHNS HOPKINS UNIV,SCH MED,DEPT RADIOL,MED IMAGING LAB,BALTIMORE,MD 21205
关键词
MRI; TAGGING; OPTIMIZATION; FAST-SCAN;
D O I
10.1002/mrm.1910310508
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Contrast between tagged and nontagged myocardium was investigated using rapid gradient echo segmented k-space CINE MRI. The transient behavior of magnetization was measured in stationary and moving phantoms using gradient recalled acquisition in steady-state GRASS and spoiled GRASS (SPGR) sequences with TR approximate to 7 ms and TE approximate to 2.5 ms. Bloch equation simulations were used to compute theoretical results. Understanding the transient behavior of magnetization is important because tags only persist in the myocardium during the nonequilibrium transition to steady state. The transition to steady state for both SPGR and GRASS is reproducible after one heartbeat, and including unprocessed data from the first heartbeat leads to image artifacts. In a moving phantom, simulations and experimental results showed that GRASS and SPGR are essentially equivalent. Tag-tissue contrast in SPGR was very sensitive to imaging tip angle. The optimum tip angle for the scanning parameters used in this study was 11 degrees.
引用
收藏
页码:521 / 525
页数:5
相关论文
共 13 条
[1]   CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE [J].
ATKINSON, DJ ;
EDELMAN, RR .
RADIOLOGY, 1991, 178 (02) :357-360
[2]   MR IMAGING OF MOTION WITH SPATIAL MODULATION OF MAGNETIZATION [J].
AXEL, L ;
DOUGHERTY, L .
RADIOLOGY, 1989, 171 (03) :841-845
[3]   ELIMINATION OF TRANSVERSE COHERENCES IN FLASH MRI [J].
CRAWLEY, AP ;
WOOD, ML ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (03) :248-260
[4]  
HENDELMAN RM, 1985, MED PHYS, V12, P232
[5]   VERY SLOW INPLANE FLOW WITH GRADIENT ECHO IMAGING [J].
HENKELMAN, RM ;
MCVEIGH, ER ;
CRAWLEY, AP ;
KUCHARCZYK, W .
MAGNETIC RESONANCE IMAGING, 1989, 7 (04) :383-393
[6]  
MCVEIGH E, 1993, PHYSICS MRI
[7]   NONINVASIVE MEASUREMENT OF TRANSMURAL GRADIENTS IN MYOCARDIAL STRAIN WITH MR IMAGING [J].
MCVEIGH, ER ;
ZERHOUNI, EA .
RADIOLOGY, 1991, 180 (03) :677-683
[8]   CARDIAC TAGGING WITH BREATH-HOLD CINE MRI [J].
MCVEIGH, ER ;
ATALAR, E .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) :318-327
[9]   CALCULATION OF 3-DIMENSIONAL LEFT-VENTRICULAR STRAINS FROM BIPLANAR TAGGED MR IMAGES [J].
MOORE, CC ;
ODELL, WG ;
MCVEIGH, ER ;
ZERHOUNI, EA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (02) :165-175
[10]  
MOORE CC, IN PRESS RADIOLOGY