摘要
It has been suggested that the invasion of microbes into the catheter tract occurs mainly at the time of catheter insertion. To investigate whether the presence of an antimicrobial environment during the initial period after insertion is sufficient to reduce the risk of subsequent catheter colonization and infection, we evaluated the use of benzalkonium chloride-heparin bonded (BZK-hep) central venous catheters, which exhibit short-lived surface antimicrobial activity, using a rat subcutaneous model. Bacterial adherence on these catheters was determined, seven days after challenging the insertion site with 10(6) cfu of Staphylococcus aureus. A chlorhexidine-silver sulphadiazine impregnated catheter (Arrowg(+)ard), with longer lasting surface antimicrobial activity, and a hydrophilic coated catheter ('Hydrocath'), were evaluated simultaneously for comparison. Unlike Arrowg(+)ard antiseptic catheters, BZK-hep 'Hydrocath' and control catheters had significant bacterial adherence on their surface. Arrowg(+)ard catheters were colonized in 19% of the animals compared with 100% in all the other groups (P<0.05; mean cfu cm(-2): control=1.3 x 10(6), BZK-hep=4.3 x 10(5), Hydrocath=2 x 10(5), Arrowg(+)ard=71). Our results indicate that catheters with short-lived surface antimicrobial activity are unlikely to provide long-term protection against catheter-related infection. The efficacy of Arrowg(+)ard catheters may be due to the initial high rate of kill and prolonged antimicrobial activity.
引用
收藏
页码:201 / 210
页数:10
相关论文
共 34 条
  • [1] Kamal, Pfaller, Rempe, Jebson, Reduced intravascular catheter-infection by antibiotic bonding: a prospective randomized control trial, JAMA, 265, pp. 2364-2368, (1991)
  • [2] Mermel, McCormick, Springman, Maki, The pathogenesis and epidemiology of catheter-related infection with pulmonary artery Swan-Ganz catheters a prospective study utilizing molecular subtyping, The American Journal of Medicine, 91, pp. 3B-197S, (1991)
  • [3] Jansen, Jansen, Peters, Pulverer, In vitro efficacy of a central venous catheter (‘Hydrocath’) loaded with teicoplanin to prevent bacterial colonization, J Hosp Infect, 22, pp. 93-107, (1992)
  • [4] Jansen, Schareina, Treitz, Antibiotic-containing polyurethanes for the prevention of foreign-body infections, Polym Mat Sci Eng, 59, pp. 794-797, (1988)
  • [5] Trooskin, Donetz, Harvey, Greco, Prevention of catheter sepsis by antibiotic bonding, Surgery, 97, pp. 547-551, (1985)
  • [6] Modak, Sampath, Development and evaluation of a new polyurethane central venous antiseptic catheter: reducing central venous catheter infections, Complications in Surgery, 11, pp. 23-28, (1992)
  • [7] Tebbs, Elliott, Modification of central venous catheter polymers to prevent in vitro microbial colonisation, Eur J Clin Microbiol Infect Dis, 13, pp. 111-117, (1994)
  • [8] Miller, Venus, Mathru, Comparison of the sterility of long-term central venous catheterization using single lumen, triple lumen and pulmonary artery catheters, Crit Care Med, 12, pp. 634-637, (1984)
  • [9] Prayer, Silva, Colonization of central venous catheters, Southern Medical Journal, 77, pp. 458-461, (1984)
  • [10] Sitzmann, Townsend, Siler, Bartlett, Septic and technical complications of central venous catheterization, Ann Surg, 202, pp. 766-770, (1985)