FUNCTIONAL DESIGN-FEATURES AND INITIAL PERFORMANCE-CHARACTERISTICS OF A MAGNETIC-IMPLANT GUIDANCE-SYSTEM FOR STEREOTAXIC NEUROSURGERY

被引:43
作者
MCNEIL, RG
RITTER, RC
WANG, B
LAWSON, MA
GILLIES, GT
WIKA, KG
QUATE, EG
HOWARD, MA
GRADY, MS
机构
[1] UNIV VIRGINIA,DEPT PHYS,CHARLOTTESVILLE,VA 22901
[2] UNIV VIRGINIA,DEPT BIOMED ENGN,CHARLOTTESVILLE,VA 22908
[3] UNIV VIRGINIA,DEPT MECH AEROSP & NUCL ENGN,CHARLOTTESVILLE,VA 22901
[4] UNIV VIRGINIA,DEPT COMP SCI,CHARLOTTESVILLE,VA 22901
[5] UNIV VIRGINIA,DEPT NUCL ENGN & ENGN PHYS,CHARLOTTESVILLE,VA 22901
[6] WANG NMR INC,LIVERMORE,CA 94550
[7] STEREOTAXIS INC,LIVERMORE,CA 94550
[8] UNIV WASHINGTON,HARBORVIEW MED CTR,DEPT NEUROSURG,SEATTLE,WA 98104
关键词
D O I
10.1109/10.398640
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A helmet with a roughly cubic array of six superconducting coils is used to apply force on a small permanent magnet pellet in brain or in brain phantom material. This apparatus, called the Magnetic Stereotaxis System, will be used to deliver drugs and other therapies directly into deep brain tissues, under control of a computer and fluoroscopic imaging system. This paper considers only the force application aspects of the instrument. The primary design features of the helmet and power supply controls are presented, along with field plot data and single-axis motion results. The field plot data show that agreement with the finite-element iron-free field calculations is sufficiently high (>1%) for the instrument. These preliminary motion data indicate accuracy better than 2 mm for the impulsive pellet motion, even though the visual position observations had significantly greater error than the completed imaging system will have. The companion paper will take up analysis of the control aspects of the motion, and our recent solutions to difficulties found in the experimental work described here.
引用
收藏
页码:793 / 801
页数:9
相关论文
共 14 条
[11]   ELECTROOPTIC IMAGING CHAIN FOR A BIPLANAR FLUOROSCOPE FOR NEUROSURGERY - MAGNETIC-FIELD SENSITIVITY AND CONTRAST MEASUREMENTS [J].
RAMOS, PA ;
ALLISON, SW ;
MOLLOY, JA ;
LAWSON, MA ;
QUATE, EG ;
RITTER, RC ;
GILLIES, GT ;
GRADY, MS ;
HOWARD, MA .
OPTICAL ENGINEERING, 1993, 32 (07) :1644-1656
[12]  
RITTER RC, UNPUB J NEUROSURG
[13]  
RITTER RC, 1992, INNOV TECH BIOL MED, V13, P437
[14]  
WIKA KG, 1992, UVA124620MANE93102 U, P82