FACTORS INFLUENCING INDOOR AIR-QUALITY IN HONG-KONG - MEASUREMENTS IN OFFICES AND SHOPS

被引:16
作者
LIAO, SST
BACONSHONE, J
KIM, YS
机构
[1] HANYANG UNIV,INST ENVIRONM & IND MED,SEOUL 133,SOUTH KOREA
[2] UNIV HONG KONG,SOCIAL SCI RES CTR,HONG KONG,HONG KONG
关键词
D O I
10.1080/09593339109385065
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Comparisons of levels of respirable suspended particulates, carbon monoxide, carbon dioxide, nitrogen dioxide, volatile organic compounds and nicotine have been made between indoor and outdoor air in 35 street-level shops and 35 offices in Hong Kong. Additionally, counts of bacteria and fungi were made indoors. In shops, the study showed that the air quality was principally determined by outdoor air, with highly significant correlations between indoor and outdoor levels of RSP, CO and NO2. The levels of these substances were significantly lower in offices. Measurement of analytes related to tobacco smoking showed extremely low levels of environmental tobacco smoke in both shops and offices, but the overall numbers of smokers in such establishments was small. For offices, occupier complaints regarding drowsiness, headache and symptoms of eye, nose and respiratory tract irritation were positively associated with CO2 levels. NO2, CO, toluene and benzene levels did not show any relationship to occupier comfort or sick-building syndrome complaints.
引用
收藏
页码:737 / 745
页数:9
相关论文
共 23 条
[11]   MEASUREMENTS OF ENVIRONMENTAL TOBACCO-SMOKE IN AN AIR-CONDITIONED OFFICE BUILDING [J].
PROCTOR, CJ ;
WARREN, ND ;
BEVAN, MAJ .
ENVIRONMENTAL TECHNOLOGY LETTERS, 1989, 10 (11) :1003-1018
[12]  
TSUI WS, 1990, SICK BUILDING SYNDRO
[13]   THE TEAM STUDY - PERSONAL EXPOSURES TO TOXIC-SUBSTANCES IN AIR, DRINKING-WATER, AND BREATH OF 400 RESIDENTS OF NEW-JERSEY, NORTH-CAROLINA, AND NORTH-DAKOTA [J].
WALLACE, LA ;
PELLIZZARI, ED ;
HARTWELL, TD ;
SPARACINO, C ;
WHITMORE, R ;
SHELDON, L ;
ZELON, H ;
PERRITT, R .
ENVIRONMENTAL RESEARCH, 1987, 43 (02) :290-307
[14]  
YANAGISAWA Y, 1990, J JAPAN SOC AIR POLL, V15, P316
[15]  
1990, LANCET 1222, P48
[16]  
1987, PCAM125 NAT I OCC SA
[17]  
1983, MDHS14 OCC MED HYG L
[18]  
1988, GLOBAL ENV MONITORIN
[19]  
1990, ENV HONG KONG 1990
[20]  
1981, INDOOR POLLUTANTS