DEVELOPMENT OF AN EXTREMELY FLEXIBLE AUTOMATIC ANALYZER WITH INTEGRATED BIOSENSORS FOR ONLINE CONTROL OF FERMENTATION PROCESSES

被引:39
作者
SCHUHMANN, W [1 ]
WOHLSCHLAGER, H [1 ]
HUBER, J [1 ]
SCHMIDT, HL [1 ]
STADLER, H [1 ]
机构
[1] INST BIOANALYT GGMBH,D-37079 GOTTINGEN,GERMANY
关键词
SEQUENTIAL-INJECTION ANALYSIS; FLOW INJECTION; BIOSENSORS; ONLINE PROCESS CONTROL; COMPLEX INJECTION PROFILES;
D O I
10.1016/0003-2670(95)00300-O
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a highly flexible sequential-injection system for the on-line control of fermentation processes is described. The developed system shows a significantly improved flexibility and adaptability to the needs of a particular fermentation process to be monitored as compared with conventional now-injection systems. The number of necessary hardware components has also been drastically decreased, and the minimal injection volume decreased to 3-5 mu l allowing improved dilution of an injected sample plug and improved mixing of coinjected reagents. A dilution factor can be adjusted to between 1 and 100 due to controlled dispersion of the injected sample plug within the tube system by choosing an appropriate injection volume. Due to the symmetrical design of the injection manifold and the versatile control software, complex injection profiles can be obtained that are necessary to coinject a sample together with a reagent or a sample together with one or two standard solutions for immediate recalibration. The system is fully automated, and the specially developed software package comprises automatic calibration and recalibration with up to 5 standard solutions, real-time calculation of the actual concentration values based on the most recent calibration data, documentation of the fermentation course, and injection of samples from up to 4 sampling sites with variable time basis.
引用
收藏
页码:113 / 122
页数:10
相关论文
共 24 条
[1]   NOVEL SINGLE STANDARD CALIBRATION AND DILUTION METHOD PERFORMED BY THE SEQUENTIAL INJECTION TECHNIQUE [J].
BARON, A ;
GUZMAN, M ;
RUZICKA, J ;
CHRISTIAN, GD .
ANALYST, 1992, 117 (12) :1839-1844
[2]   CHARACTERIZATION AND APPLICATION OF PRECISE AND ROBUST FLOW-INJECTION ANALYZERS FOR ONLINE MEASUREMENT DURING FERMENTATIONS [J].
BENTHIN, S ;
NIELSEN, J ;
VILLADSEN, J .
ANALYTICA CHIMICA ACTA, 1991, 247 (01) :45-50
[3]   NOVEL FLOW-INJECTION ANALYSIS METHOD FOR BIOPROCESS MONITORING [J].
CHUNG, S ;
WEN, XW ;
VILHOLM, K ;
DEBANG, M ;
CHRISTIAN, G ;
RUZICKA, J .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :77-85
[4]  
DECASTRO MDL, 1992, ANAL CHIM ACTA, V261, P425
[5]   DIRECT LINEAR PLOT - NEW GRAPHICAL PROCEDURE FOR ESTIMATING ENZYME KINETIC-PARAMETERS [J].
EISENTHAL, R ;
CORNISH-BOWDEN, A .
BIOCHEMICAL JOURNAL, 1974, 139 (03) :715-720
[6]   ONLINE DETERMINATION OF GLUCOSE IN BIOTECHNOLOGICAL PROCESSES - COMPARISON BETWEEN FIA AND AN INSITU ENZYME ELECTRODE [J].
FILIPPINI, C ;
SONNLEITNER, B ;
FIECHTER, A ;
BRADLEY, J ;
SCHMID, R .
JOURNAL OF BIOTECHNOLOGY, 1991, 18 (1-2) :153-160
[7]   ONLINE MONITORING AND CONTROL OF FERMENTATION PROCESSES BY FLOW-INJECTION ANALYSIS [J].
FORMAN, LW ;
THOMAS, BD ;
JACOBSON, FS .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :101-111
[8]   SEQUENTIAL INJECTION TECHNIQUE FOR AUTOMATION OF COMPLEX ANALYTICAL PROCEDURES - FLUOROMETRIC ASSAY OF FACTOR-XIII [J].
GUZMAN, M ;
POLLEMA, C ;
RUZICKA, J ;
CHRISTIAN, GD .
TALANTA, 1993, 40 (01) :81-87
[9]  
HANSEN E H, 1990, Wissenschaftliche Zeitschrift der Technischen Hochschule "Carl Schorlemmer" Leuna-Merseburg, V32, P373
[10]  
HULL RD, 1992, ANAL CHIM ACTA, V267, P1