CORRELATION OF ARTERIAL AND VENOUS-BLOOD FLOW IN THE MESENTERIC SYSTEM BASED ON MR FINDINGS

被引:25
作者
BURKART, DJ [1 ]
JOHNSON, CD [1 ]
EHMAN, RL [1 ]
机构
[1] MAYO CLIN & MAYO FDN, DEPT DIAGNOST RADIOL, 200 1ST ST SW, ROCHESTER, MN 55905 USA
关键词
D O I
10.2214/ajr.161.6.8249742
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to determine if a consistent relationship exists between (1) flow in the portal vein and superior mesenteric vein and (2) flow in the mesenteric arteries. SUBJECTS AND METHODS. Cine phase-contrast methods were used to determine volumetric flow in the celiac axis, superior mesenteric artery, portal vein, and superior mesenteric vein in 11 healthy volunteers. RESULTS. The mean (+/- SD) volumetric flow rates in the celiac axis, superior mesenteric artery, superior mesenteric vein, and portal vein were 9.9 +/- 3.2, 6.0 +/- 1.8, 5.7 +/- 2.0, and 13.7 +/- 1.8 ml/min per kilogram, respectively. A strong correlation was found between measured mesenteric arterial blood flow, defined as the sum of flow in the celiac axis and the superior mesenteric artery, and portal venous flow (r=.97, p = .00002). Good agreement was found between flow in the superior mesenteric artery and that in the superior mesenteric vein (r = .98; p = .00001; bias = 20 ml/min). CONCLUSION. There is a consistent relationship between MR measurements of flow in the portal or superior mesenteric vein and the measured flow in the arteries supplying those veins. Flow in the superior mesenteric vein is an accurate predictor of flow in the superior mesenteric artery.
引用
收藏
页码:1279 / 1282
页数:4
相关论文
共 17 条
  • [1] VOLUMETRIC FLOW-RATES IN THE PORTAL VENOUS SYSTEM - MEASUREMENT WITH CINE PHASE-CONTRAST MR IMAGING
    BURKART, DJ
    JOHNSON, CD
    MORTON, MJ
    WOLF, RL
    EHMAN, RL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) : 1113 - 1118
  • [2] BURNS GP, 1967, SURG FORUM, V18, P313
  • [3] RIGHT AND LEFT LUNG PERFUSION - INVITRO AND INVIVO VALIDATION WITH OBLIQUE-ANGLE, VELOCITY-ENCODED CINE MR IMAGING
    CAPUTO, GR
    KONDO, C
    MASUI, T
    GERACI, SJ
    FOSTER, E
    OSULLIVAN, MM
    HIGGINS, CB
    [J]. RADIOLOGY, 1991, 180 (03) : 693 - 698
  • [4] SEVERITY OF AORTIC REGURGITATION - INTERSTUDY REPRODUCIBILITY OF MEASUREMENTS WITH VELOCITY-ENCODED CINE MR-IMAGING
    DULCE, MC
    MOSTBECK, GH
    OSULLIVAN, M
    CHEITLIN, M
    CAPUTO, GR
    HIGGINS, CB
    [J]. RADIOLOGY, 1992, 185 (01) : 235 - 240
  • [5] THE APPLICATION OF PHASE-SHIFTS IN NMR FOR FLOW MEASUREMENT
    FIRMIN, DN
    NAYLER, GL
    KILNER, PJ
    LONGMORE, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) : 230 - 241
  • [6] FRAYNE R, 1992, SOC MAGNETIC RESONAN, P2904
  • [7] T1-WEIGHTED SNAPSHOT GRADIENT-ECHO MR IMAGING OF THE ABDOMEN
    HOLSINGERBAMPTON, AE
    RIEDERER, SJ
    CAMPEAU, NG
    EHMAN, RL
    JOHNSON, CD
    [J]. RADIOLOGY, 1991, 181 (01) : 25 - 32
  • [8] HOPKINSON BR, 1968, SURGERY, V63, P970
  • [9] JAGER K, 1986, J VASC SURG, V3, P462
  • [10] KOSLIN DB, 1992, SEMIN ULTRASOUND CT, V13, P34