ARTIFACTS DUE TO STIMULUS CORRELATED MOTION IN FUNCTIONAL IMAGING OF THE BRAIN
被引:357
作者:
HAJNAL, JV
论文数: 0引用数: 0
h-index: 0
机构:
HAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,MED RES COUNCIL,CYCLOTRON UNIT,LONDON W12 0HS,ENGLANDHAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,MED RES COUNCIL,CYCLOTRON UNIT,LONDON W12 0HS,ENGLAND
HAJNAL, JV
[1
]
MYERS, R
论文数: 0引用数: 0
h-index: 0
机构:
HAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,MED RES COUNCIL,CYCLOTRON UNIT,LONDON W12 0HS,ENGLANDHAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,MED RES COUNCIL,CYCLOTRON UNIT,LONDON W12 0HS,ENGLAND
MYERS, R
[1
]
OATRIDGE, A
论文数: 0引用数: 0
h-index: 0
机构:
HAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,MED RES COUNCIL,CYCLOTRON UNIT,LONDON W12 0HS,ENGLANDHAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,MED RES COUNCIL,CYCLOTRON UNIT,LONDON W12 0HS,ENGLAND
OATRIDGE, A
[1
]
SCHWIESO, JE
论文数: 0引用数: 0
h-index: 0
机构:
HAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,MED RES COUNCIL,CYCLOTRON UNIT,LONDON W12 0HS,ENGLANDHAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,MED RES COUNCIL,CYCLOTRON UNIT,LONDON W12 0HS,ENGLAND
SCHWIESO, JE
[1
]
YOUNG, IR
论文数: 0引用数: 0
h-index: 0
机构:
HAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,MED RES COUNCIL,CYCLOTRON UNIT,LONDON W12 0HS,ENGLANDHAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,MED RES COUNCIL,CYCLOTRON UNIT,LONDON W12 0HS,ENGLAND
YOUNG, IR
[1
]
BYDDER, GM
论文数: 0引用数: 0
h-index: 0
机构:
HAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,MED RES COUNCIL,CYCLOTRON UNIT,LONDON W12 0HS,ENGLANDHAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,MED RES COUNCIL,CYCLOTRON UNIT,LONDON W12 0HS,ENGLAND
BYDDER, GM
[1
]
机构:
[1] HAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,MED RES COUNCIL,CYCLOTRON UNIT,LONDON W12 0HS,ENGLAND
MAGNETIC RESONANCE IMAGING;
FUNCTIONAL IMAGING;
STIMULUS CORRELATED MOTION;
ARTIFACT;
D O I:
10.1002/mrm.1910310307
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
To assess the effect of stimulus correlated motion on the appearance of functional magnetic resonance images, conventional visual and motor protocols were each performed by four normal volunteers and an image co-registration technique was used to retrospectively monitor subject motion. In three studies synthetic data sets were constructed from single baseline images using the positional information obtained from the co-registration procedure. Cumulative difference images were then created from both the synthetic and functional image sets. Stimulus correlated motion was detected in all eight studies and the synthetic cumulative difference images showed striking similarities to the equivalent functional images in each case.