MEASUREMENTS AND CORRECTION OF THE PEP INTERACTION REGION QUADRUPOLE MAGNETS

被引:9
作者
MAIN, RM
TANABE, JT
HALBACH, K
机构
[1] Lawrence Berkeley Laboratory, Berkely
关键词
D O I
10.1109/TNS.1979.4330687
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Lenses for the intersection regions of PEP must be pure quadrupole over the entire magnet aperture to within 1:104. Correction of the magnet and its end fringe regions to this accuracy requires measurement of the field quality (relative field harmonic component amplitudes at the pole radius) to 1:105 through the 30th harmonic. Equipment developed for these measurements and the techniques used for field correction are described. Copyright © 1979 by The Institute of Electrical and Electronics Engineers, Inc.
引用
收藏
页码:4030 / 4032
页数:3
相关论文
共 7 条
[1]  
ASNER A, 1971, MAE712 SI NOT
[2]   PEP INSERTION QUADRUPOLE DESIGN-FEATURES [J].
AVERY, RT ;
CHAN, T ;
HALBACH, K ;
MAIN, R ;
TANABE, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (03) :4033-4035
[3]   FIRST ORDER PERTURBATION EFFECTS IN IRON-DOMINATED 2-DIMENSIONAL SYMMETRICAL MULTIPOLES [J].
HALBACH, K .
NUCLEAR INSTRUMENTS & METHODS, 1969, 74 (01) :147-&
[4]  
HALBACH K, 1976, EFFECT VARIABLE MEAS
[5]  
HALBACH K, 1978, ANAL ERRORS EXPT DET
[6]  
MAIN R, M4959 LBL ENGR NOT
[7]  
TANABE J, M4915 LBL ENGR NOT