PEP INSERTION QUADRUPOLE DESIGN-FEATURES

被引:4
作者
AVERY, RT
CHAN, T
HALBACH, K
MAIN, R
TANABE, J
机构
[1] Lawrence Berkeley Laboratory, Berkeley
关键词
D O I
10.1109/TNS.1979.4330688
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The insertion quadrupoles for the PEP storage ring must have a very uniform gradient to focus thecirculating beams to a very small size at the interaction point for high luminosity. Quads have been built which achieve the desired field within the full pole aperture radius to approximately one part in 104. The design features which permitted this achievement are described. Copyright © 1979 by The Institute of Electrical and Electronics Engineers, Inc.
引用
收藏
页码:4033 / 4035
页数:3
相关论文
共 6 条
[1]   FIRST ORDER PERTURBATION EFFECTS IN IRON-DOMINATED 2-DIMENSIONAL SYMMETRICAL MULTIPOLES [J].
HALBACH, K .
NUCLEAR INSTRUMENTS & METHODS, 1969, 74 (01) :147-&
[2]  
HALBACH K, 1967, 2ND P INT C MAGN TEC
[3]  
HALBACH K, 1969, USRL18916
[4]  
HALBACH K, 1968, NUCL I METH, V64, P275
[5]   MEASUREMENTS AND CORRECTION OF THE PEP INTERACTION REGION QUADRUPOLE MAGNETS [J].
MAIN, RM ;
TANABE, JT ;
HALBACH, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (03) :4030-4032
[6]   DEVICE TO MEASURE QUADRUPOLE GRADIENT-LENGTH PRODUCT [J].
REAGAN, D .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (03) :4058-4060