NEW WHOLE-BLOOD ANALYZERS AND THEIR IMPACT ON CARDIAC AND CRITICAL CARE

被引:57
作者
KOST, GJ
机构
[1] School of Medicine, University of California, Davis, CA
关键词
BIOSENSORS; IONIZED CALCIUM; IONIZED MAGNESIUM; HYBRID LABORATORY; PERFORMANCE MAPS; POINT-OF-CARE TESTING; PATIENT-FOCUSING; QUALITY PATHS;
D O I
10.3109/10408369309084667
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Miniaturized whole blood biosensors, patient-focused hospitals, and rising expectations of patients and physicians are shifting laboratory diagnostics to the point of care. Expanding transplantation and intensive care are increasing the need for rapid test results. Whole blood analysis improves accuracy, eliminates centrifugation, reduces response time, and conserves blood volume, Several hand-held, and over 20 portable or transportable whole blood instruments are now available. Criteria for instrument evaluation include test menus, point-of-care features, analysis time, on-site performance, and information integration. Whole blood analyzers measure several vital indicators (pO2, pCO2, pH, hematocrit, K-, Ca2+, Na+, Cl-, glucose, and lactate) simultaneously in less than 2 min with less than 200 mul of whole blood. Other in vitro tests are available (Mg2+, osmolality, CO2 content, urea nitrogen, beta-hydroxybutyrate, hemoglobin. coagulation) or under development (HCO3- phosphorus). Some can be monitored in vivo (O2 saturation, pO2, pCO2, pH, glucose) or ex vivo. The clinical impact is demonstrated by ionized calcium, now established in importance for cardiac and neurologic problems, and ionized magnesium, a promising new measurement. The hybrid laboratory (a composite of conventional clinical laboratory and patient-focused testing), performance maps, and quality paths facilitate implementation of new whole blood analyzers for optimal support of cardiac and critical care, and improved patient outcomes (prospects).
引用
收藏
页码:153 / 202
页数:50
相关论文
共 416 条
[21]  
BAER D M, 1992, Clinical Chemistry, V38, P1138
[22]  
BAER DM, 1990, CHEST, V97, pS191
[23]  
BAER DM, 1993, CLIN CHEM, V39, P9
[24]   BEDSIDE BLOOD COMPATIBILITY TESTING [J].
BAGLIN, T ;
OUWEHAND, W ;
VOAK, D ;
WATERS, AH ;
GUNSON, HH ;
LLOYD, E .
LANCET, 1990, 336 (8724) :1196-1197
[25]  
BAISDEN CR, 1985, OFFICE PRACTICE LABO
[26]  
BARBOUR RL, 1991, P AM SOC MAGNESIUM R
[27]  
BARLOW IM, 1988, CLIN CHEM, V34, P2371
[28]  
BARNETT RN, 1978, AM J CLIN PATHOL, V69, P520
[29]   EFFECT OF HEMATOCRIT CONCENTRATION ON BLOOD-GLUCOSE VALUE DETERMINED ON GLUCOMETER-II [J].
BARREAU, PB ;
BUTTERY, JE .
DIABETES CARE, 1988, 11 (02) :116-118
[30]   EVALUATION OF A BLOOD-GAS AND CHEMISTRY MONITOR FOR USE DURING SURGERY [J].
BASHEIN, G ;
GREYDANUS, WK ;
KENNY, MA .
ANESTHESIOLOGY, 1989, 70 (01) :123-127